NuTone Advantage CV850 Installation Instructions Manual Download Page 9

9

Use the following procedures for installation in existing construction.

Starting from farthest wall inlet location, install each inlet as described
below. Working back toward power unit, connect each inlet line and
branch line into main trunk line. See page 5. Complete low voltage wiring
as main trunk line is continued back to power unit. Mount power unit and
complete wiring. See page 8.

1. See Figure 29. A small ‘pilot’ or ‘locating’ hole can be drilled behind

baseboard toe strip to determine proper location of 2

1

2

" diameter tubing

hole in sole plate.

2. Measure the total thickness of the wall, including baseboard. One half of

this wall thickness measured from the pilot hole (dimension ‘X’) will
determine the proper location of the 2

1

2

" tubing hole in the sole plate.

3. Once desired inlet locations have been determined, cut a 2

1

2

" hole in

sole plate directly in line with proposed inlet location. Check through
tubing hole to be sure no obstruction exists.

4. Be sure tubing hole is centered in sole plate and directly in line with

proposed wall inlet cutout.

BASEBOARD

TOE STRIP

PILOT HOLE

“X”

SOLE PLATE

FIGURE 29

NOTE: If 330 Wall Inlet is being used refer to Model 330 Wall Inlet 
Installation on next page.

5. If area is clear, cut an inlet opening in the wall approximately 18" above the floor. 

Make sure wall opening and 2

1

2

" tube hole line up (Figure 30).

6. Cut a length of tubing that will extend from inlet opening to a point below floor level 

(or above ceiling level in attic installation). Tape low voltage wire to tube and insert tube
through predrilled hole to a level opposite the wall opening.

7. Apply cement to tube and install flanged wall fitting. Make sure fitting is well seated 

and sealed (Figure 31).

8. Remove plaster frame from mounting bracket. Pull low voltage wire through hole in 

bracket and insert bracket into cutout. Secure bracket to flanged fitting with four screws
provided. Be sure seal is secure between flange fitting and 
mounting bracket (Figure 32).

9. Attach the low voltage wires to terminal screws on back of wall 

inlet (Figure 33). If using 361 Rough-in with CI370 Series Inlets,

refer to instructions on page 6, step 3, shown in Figure 18.

10. Insert wall inlet into bracket and secure with the two screws 

provided (Figure 34).

2

1

/

2

"

2

9

/

16

"

3

1

/

16

"

18"

FIGURE 30

FIGURE 32

FIGURE 33

FIGURE 34

LOW

VOLTAGE

WIRING

FLANGED

FITTING

FIGURE 31

INSTALLATION IN EXISTING CONSTRUCTION

NOTE: If the wall for mounting the Model 360 inlet is less
than 

1

2

", a spacer must be used. 

See Figure 20 on page 6 as

a guide.

WALL INLET INSTALLATION

MODEL CI370 or 360 SERIES INLETS (361 Rough-In)

Summary of Contents for Advantage CV850

Page 1: ...alling the Tubing 5 Wall Inlet Installation Models CI370 360 Wall Inlets 6 Model 330 Wall Inlet 6 Model CI390 Wall Inlet Electrified Inlet 7 POWER UNIT INSTALLATION 8 Dimensional Chart 8 Mounting 8 Tu...

Page 2: ...TRUNK LINE INLET LINE INLET EXHAUST INTAKE POWER UNIT BASEMENT TRUNK LINE FIGURE 2 FIGURE 1 Like the two story house the split level installation commonly calls for a two level trunk line Here the po...

Page 3: ...procedure to determine each additional inlet location always working toward the power unit 5 Be sure tubing will not interfere with electrical plumbing or other mechanical installations 6 Locate inlet...

Page 4: ...lso be nailed to the front edge of the stud See face mounting illustrated For face mounting use locating tabs on bracket for proper alignment 4 Refer to Figure 8 Remove cardboard from plaster guard fr...

Page 5: ...r to Figure 13 Remove burrs from both inside and outside of tubing 10 Before cementing pre assemble section to inlet fitting check for proper length 11 Refer to Figure 14 Apply PVC cement Model 379 to...

Page 6: ...tor cable used to connect the inlet to the power unit does not have a polarity marking and the CI370 is wired backwards no damage will result however the indicator will light RED instead of GREEN when...

Page 7: ...1 2 of this sheathing exposed inside of the outlet box Fold the 6 of black and white wire into the outlet box Leave the wires to be connected by the electrician when plug receptacles are being install...

Page 8: ...on or break down grounding provides a path of least resistance for electric current to reduce the risk of electric shock This appliance is equipped with a cord having an equipment grounding conductor...

Page 9: ...on next page 5 If area is clear cut an inlet opening in the wall approximately 18 above the floor Make sure wall opening and 21 2 tube hole line up Figure 30 6 Cut a length of tubing that will extend...

Page 10: ...29 16 square hole in floor Center line of inlet must be located at least 21 2 from wall to allow cover to be opened when hose is inserted 2 Determine direction of tubing and attach appropriate flange...

Page 11: ...is inserted and switched on if applicable If using CI370 Indicating Inlet be sure LED on inlet is green when hose is inserted switched on If Central Cleaning hose is not available at the time a short...

Page 12: ...not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you NUTONE S OBLIGATION TO REPAIR OR REPLACE AT NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND E...

Page 13: ...ie 5 Installation des Prises Murales Mod les CI370 et 360 Prises d Aspiration Murales 6 Mod le 330 Prise Murale 6 Mod le CI390 Prise Murale Electrifi e 7 INSTALLATION DU GROUPE D ASPIRATION 8 Tableau...

Page 14: ...cessite commun ment une ligne principale deux niveaux Dans cet exemple le groupe d aspiration est mont dans le garage La tuyauterie d admission expos e monte le long du mur du garage jusqu au grenier...

Page 15: ...vous dirigeant toujours vers le groupe d aspiration 5 Soyez certain que la tuyauterie n interf re pas avec des installations lectriques de plomberie ou d autres installations m caniques 6 Placez les...

Page 16: ...illustration du montage de face Pour le montage de face utilisez les pattes d alignement des supports pour un alignement correct 4 Voyez la figure 8 Enlevez le carton du cadre protecteur Utilisez les...

Page 17: ...coller pr assemblez la section jusqu au raccord de la prise pour v rifier que la longueur soit correcte 11 Voyez la figure 14 Appliquez la colle PCV Mod le 379 l ext rieur du tuyau Couvrez le tube 2 5...

Page 18: ...y aura aucun dommage toutefois l indicateur fournira une lumi re ROUGE plut t que VERTE lorsque le boyau sera ins r dans la prise Pour corriger cette imperfection inversez simplement les deux raccord...

Page 19: ...Incorporez le c ble de 15 24 cm noir et blanc dans la bo te de sortie Laissez les c bles tre connect s par un lectricien lors de l installation des r cepteurs de prises Attention l utilisation d outi...

Page 20: ...reil doit tre mis la terre En cas de d faillance ou de panne la mise la terre constitue une voie de moindre r sistance pour le courant lectrique ce qui r duit le risque d un choc lectrique Cet apparei...

Page 21: ...approximativement 45 cm du sol Assurez vous que l ouverture du mur et le trou de la tuyauterie de 6 35 cm de diam tre sont align s Figure 30 6 Coupez une longueur de tube qui pourra s tendre de l ouve...

Page 22: ...du couvercle au moment de l insertion du boyau 2 D terminez la direction de la tuyauterie et attachez le raccord bride appropri au support de montage avec les quatre 4 vis fournies Assurez vous que l...

Page 23: ...pe d aspiration n est pas disponible ce moment un petit bout de c ble peut servir tablir le contact entre les deux contacts de la prise murale pour vous permettre d activer le groupe d aspiration V ri...

Page 24: ...LA R PARATION PAR NUTONE SA PROPRE DISCR TION DE TOUT PRODUIT OU PI CE D FECTUEUX CONSTITUE LE SEUL REM DE DE L ACHETEUR EN VERTU DE CETTE GARANTIE NUTONE NE PEUT TRE TENUE RESPONSABLE DES DOMMAGES I...

Page 25: ...i n de los enchufes de pared Enchufes de pared modelos CI370 y 360 6 Enchufe de pared modelo 330 6 Enchufe de pared modelo CI390 Enchufe electrificado 7 INSTALACION DE LA UNIDAD DE POTENCIA 8 Diagrama...

Page 26: ...se coloca en el garaje El entubado de entrada corre sin cubrir desde el fondo de la pared del garaje hacia dentro del tico de la secci n a nivel de la tierra Dos l neas secundarias conectan esta part...

Page 27: ...sario Determine la ubicaci n de cada enchufe adcional con el mismo procedimiento siempre en direcci n hacia la unidad de potencia 5 Aseg rese de que el entubado no interfiera con las instalaciones el...

Page 28: ...traci n del montaje superficial Para el montaje superficial use las aletas localizadoras para asegurar el alineamiento correcto del encastramiento 4 V ase la Figura 8 Quite el cart n del marco protect...

Page 29: ...s correcto 11 V ase la Figura 14 Aplique cemento para PVC modelo 379 al exterior del entubado Cubra el entubado hasta 2 5 cm del extremo Cu dese de no poner cemento al interior del tubo 12 V ase la Fi...

Page 30: ...embargo el indicador se iluminar en ROJO en vez de VERDE al insertar la manguera en el enchufe Para remediar esta condici n invierta las conexiones al enchufe CI370 4 Dirija el alambre que sobra por...

Page 31: ...del mismo descubierto dentro de la caja de toma Doble las 15 2 cm de alambre blanco y negro hacia dentro de la caja de toma Deje los alambres para ser conectados por un electricista cuando se instalen...

Page 32: ...rato debe ser conectado a tierra Si funciona de un modo defectuoso o se aver a la conexi n a tierra le proporciona a la corriente el ctrica una v a f cil que reduce el riesgo de choque el ctrico Este...

Page 33: ...la pared a aproximadamente 45 cm del piso Aseg rese de que se alineen la abertura de pared y el agujero de tubo de 6 3 cm Figura 30 6 Corte un largo de entubado que se extender desde la abertura de e...

Page 34: ...cuando se inserte la manguera 2 Determine la direcci n del entubado y sujete el accesorio con bridas apropiado a la abrazadera de montaje con cuatro 4 tornillos proporcionados Aseg rese de que la brid...

Page 35: ...anguera Si la manguera de aspiraci n central no est disponible al momento se puede usar un pedazo corto de alambre en los contactos en la pared para activar la unidad de potencia Inspeccione cada ench...

Page 36: ...imitaci n arriba indicada puede que no se aplique a Ud LA OBLIGACI N DE NUTONE DE REPARAR O REEMPLAZAR A SU OPCI N SER EL NICO Y EXCLUSIVO RECURSO QUE TENDR EL COMPRADOR BAJO ESTA GARANT A NUTONE NO S...

Reviews: