WIRING

All wiring must comply with local codes and unit must be

properly grounded.
IMPORTANT: 

Use wire suitable for 90°C.

Refer to Figure 4.

1. Run 120vAC house wiring (with ground) from wall switches to 

fan location.

2. Insert and secure an approved box connector into wiring 

entrance holes.

3. Pull wires through box connector and into junction box. Tighten 

box connector.

4. Connect white wires from fan and light receptacles to white (neutral)

wire from the supply. Connect black wire to wire from fan switch.
Connect red wire to wire from light switch. Connect yellow wire to
wire from night light switch.

5. Connect the green (or bare) ground wire to the green ground lead.

POWER/BLOWER UNIT INSTALLATION

1. 

Refer to Figure 1. 

Place power/blower unit into housing so that

mounting plate's tabs insert into slots in housing.

2. Press other end of mounting plate down until it is firmly seated over

scroll and plug-in receptacles.

3. Secure mounting plate to housing with provided screw.
4. Insert motor plug into junction box receptacle.

COMPLETING INSTALLATION

1. Insert lamp plug into junction box receptacle and secure

reflector/grille assembly to motor frame with extension nut
provided. Turn extension nut until grille is flush to ceiling.

2. Install lamps 100 watt (maximum) for light, and 7 watt (maximum)

for night light.

3. Squeezing the mounting spring of the lens, insert springs into slots

on both sides of reflector. 

NOTE: Spring should be inserted

through slots in grille only. Do not insert springs into tabs on
“A” housing; position grille so that springs extend into
recessed housing area.

4. Press lens flush against reflector/grille assembly.

INSTALLATION IN EXISTING CONSTRUCTION

PLANNING

Review “INSTALLATION IN A NEW CONSTRUCTION SITE” and

follow all instructions which apply to your installation.

LOCATION:

Locate fan between ceiling joists.

WIRING AND DUCTING: 

Plan ducting wiring before proceeding with

installation. 

Refer to Figure 4 for wiring and Figure 3 for ducting.

CAUTION: Check area above planned location to be sure that:

1. Ducting can be installed or that area is sufficient for proper venting.
2. Wiring can be run to the planned location.
3. No wiring or other obstruction might interfere with installation.

INSTALLATION

1. The fan must be mounted between ceiling joists. Decide where

you want to locate the fan, and then determine where the nearest
joists are.

Locating Joists –

Lightly tap the ceiling. A hollow sound means

no joist; a solid sound means a joist is present. To be sure you
have located a joist, drill a small hole (

1

/

16

") and probe into the

ceiling with a wire.

2. Locate the joists. Drill a starter hole in the ceiling between the

joists.

3. To exactly locate the edge of joist, saw a line from hole to joist.
4. 

Refer to page 1. 

Remove power/blower unit from housing.

5. Use the housing pan as a template to mark cutout: place pan

centered between joist and trace around pan.

6. Make cutout along outside of marked line.

7. 

Refer to Figure 5. 

Install 2 x 4 cleats to both ceiling joists. In some

cases it may be necessary to use more than a single cleat on one
side. The distance between cleats must be at least 9

1

¼

8

" but not

more than 10". 

8. Remove side wiring knockout and insert and secure an approved

box connector into the wiring entrance hole.

9. Use pliers to bend both mounting tabs as flush as possible to the

side of the housing.

10. Install duct collar.
11. String wiring through box connector and connect 4" flexible duct to

duct collar.

12. Carefully push ductwork and wiring back into cutout, keeping it 

as straight as possible. Place housing into cutout.

13. Use wood screws to secure housing to cleats through four holes in

housing's pan. make sure pan is flush to finished ceiling.

14. Install Power/Blower Unit and complete installation as described

above.

CLEANING AND RELAMPING

1. Pull lens away from reflector/grille assembly.
2. Squeezing the mounting springs together, remove lens to expose

socket for relamping.

3. Use only a mild soap and water solution to clean grille and lens.

Do not use strong, abrasive cleaners.

4. After cleaning or relamping, reinstall reflector/grille assembly 

and lens as previously instructed.

FIGURE 1

WIRING
KNOCKOUTS

SCROLL

POWER/
BLOWER UNIT

REFLECTOR

LENS

WING NUT

TABS

SLOTS

Summary of Contents for 8663RM Series

Page 1: ...for use in shower or tub enclosure when used with a GFI circuit FOR BEST RESULTS When installing the Exhaust Fan Light in a new construction site install housing during the rough in construction of t...

Page 2: ...to be sure that 1 Ducting can be installed or that area is sufficient for proper venting 2 Wiring can be run to the planned location 3 No wiring or other obstruction might interfere with installation...

Page 3: ...etapa de enterramiento de la linstalaci n el ctrica de la construcci n La unidad de potencia el reflector y la rejilla deben de instalarse despu s de que el techo acabado est en su sitio PLANIFICACION...

Page 4: ...es de continuar con la instalaci n Refi rase a la Figura 4 para el cableado y a la Figura 3 para el conducto PRECAUCION compruebe el rea sobre la instalaci n planeada para asegurarse de que 1 El condu...

Page 5: ...la grille doivent tre install s apr s la finition du plafond PREPARATION DU GAINAGE ET DU CABLAGE GAINAGE 1 Utiliser une gaine ronde de 4 pounces 2 Pr voir le parcours de la gaine pour vacuation l ex...

Page 6: ...l installation Voir Figure 4 pour le c blage et Figure 3 pour le gainage ATTENTION Inspector l espace au dessus de l emplacement pr vu pour s assurer que 1 La gaine puisse tre install e ou que l espa...

Page 7: ...USE WIRING Cabledo De La Casa De 120vCA COURANT DOMESTIQUE 120 V AC DUCT COLLAR Collarn Del Conducto COLLIER DE GAINE WIRING KNOCKOUT Agujero Ciego Del Cableado PREDECOUPE DE CABLAGE MOUNTING HOLES Ag...

Page 8: ...PECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or ex...

Page 9: ...6310 RETAINING RING LENS SPRING ASSY 8663RMSA 8663RMBR 86310 000 86311 RETAINING RING LENS SPRING ASSY 8663RMAB 86311 000 12 16133 WING NUT 8663RM SERIES 16133 000 13 10034 FAN RECEPTACLE 8663RM SERIE...

Reviews: