WARNING  

  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-

JURY TO PERSONS, OBSERVE THE FOLLOWING:
1.  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 

or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service 

panel and lock the service disconnecting means to prevent 

power from being switched on accidentally. When the service 

disconnecting means cannot be locked, securely fasten a 

prominent warning device, such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by a 

qualified person(s) in accordance with all applicable codes 

and standards, including fire-rated construction codes and 

standards.

4.  Sufficient air is needed for proper combustion and exhausting 

of gases through the flue (chimney) of fuel burning equip-

ment to prevent backdrafting. Follow the heating equipment 

manufacturer’s guideline and safety standards such as those 

published by the National Fire Protection Association (NFPA), 

and the American Society for Heating, Refrigeration and Air 

Conditioning Engineers (ASHRAE), and the local code authori-

ties.

5. When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.
7.  Never place a switch where it can be reached from a tub or 

shower.

8.  A dimmer switch may be used to operate the light in this unit. 

Refer to the list of compatible dimmer switches on nutone.com.

9.  Install this unit in a flat ceiling only.
10.  For use in non fire rated installations only.
11.  Not for use in environmental air handling spaces.
12. If this unit is to be installed over a tub or shower, it must be 

marked as appropriate for the application and be connected 

to a GFCI (Ground Fault Circuit Interrupter) - protected branch 

circuit.

13.  Do not install in a ceiling thermally insulated to a value greater 

than R60.

14. This unit must be grounded.

CAUTION  

!

1.   For general ventilating use only. Do not use to exhaust 

hazardous or explosive materials and vapors.

2.   To avoid motor bearing damage and noisy and/or unbalanced 

impellers, use the cardboard protector (provided) to keep 

drywall spray, construction dust, etc. off power unit.

3.   The LED bulb used with this product twists into the bulb socket. 

Do not attempt to insert or remove bulb by pushing it 

straight in or pulling it straight down.

4.  Please read specification label on product for further 

information and requirements. 

RECESSED
LED FAN / LIGHT

READ AND SAVE THESE INSTRUCTIONS

To clean trim ring / baffle:

 Vacuum with a soft brush attachment 

or remove trim ring / baffle  and clean with a soft cloth and mild 

soap or detergent. Dry thoroughly before reinstalling.

To clean inside of housing:

 Remove trim ring / baffle and 

vacuum inside of housing with a soft brush attachment.

OPERATION

The fan and light can be operated using various combinations of 

on/off switches and controls:
•  Fan and light controlled with single on/off switch

•  Fan and light controlled with separate on/off switches

•  Fan controlled with timer control

•  Fan controlled with speed control
See “Connect Wiring” section for various wiring options.

CLEANING

MAINTENANCE

WARRANTY

Motor is permanently lubricated. Do not oil or disassemble motor.

See “Service Parts” section for a list and illustrations of service parts.

NuTone Ventilation Fan/Lights - Limited Warranty

WARRANTY PERIOD:  NuTone warrants to the original consumer purchaser of its NuTone Ventilation 

Fan/light

 

(the “Fan”) that your Fan (excluding lamps/bulbs) will be materially free from defects in 

materials or workmanship for a period of three (3) years from the date of original purchase. The 

warranty on the lamps/bulbs provided with the Fan is one (1) year and does not cover lamp/bulb 

breakage. This warranty does not cover accessories, such as speed controls, that may be purchased 

separately and installed with the Fan.
The limited warranty period for replacement parts, and for Fans repaired or replaced under this limited 

warranty, shall continue for the remainder of the original warranty period.
THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED 

TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, NuTone will, at its option, repair or replace, without charge, any product 

or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES. This war-

ranty does not cover (a) normal maintenance and service or (b) any products or parts which have been 

subject to misuse, negligence, accident, improper maintenance or repair (other than by NuTone), faulty 

installation or installation contrary to recommended installation instructions.
The duration of an implied warranty is limited to the one-year period as specified for the express 

warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above 

limitation may not apply to you.
BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT NUTONE’S OPTION, SHALL BE THE 

PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL 

NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR 

IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion 

or limitation of incidental or consequential damages, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state 

to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify NuTone at the address or telephone number stated 

below, (b) give the model number and part identification and (c) describe the nature of any defect 

in the product or part. At the time of requesting warranty service, you must present evidence of the 

original purchase date.
Broan-NuTone LLC    Hartford, Wisconsin    www.nutone.com    800-558-1711

Summary of Contents for 744LEDNT

Page 1: ...e fan and light can be operated using various combinations of on off switches and controls Fan and light controlled with single on off switch Fan and light controlled with separate on off switches Fan controlled with timer control Fan controlled with speed control See Connect Wiring section for various wiring options CLEANING MAINTENANCE WARRANTY Motor is permanently lubricated Do not oil or disas...

Page 2: ... mounting brackets into the bracket channels on the housing Bend the tabs on the cardboard protector and insert protector into opening in housing NOTE The cardboard protector shields the inside of the housing from drywall spray and construction dust Do not remove it until after construction is completed CARDBOARD PROTECTOR The ducting from this fan to the outside of the building has a strong effec...

Page 3: ...CK OF HOUSING 2 WIRE PLUS GROUND POWER CABLE GROUND TO WIRING PLATE 3 Pound in nails Remove unit temporarily and pound nails partially into joists at all four marked locations 4 Hang and secure housing Hang unit from nails Check to make sure that there will be a 1 8 gap between bottom of housing and ceiling material Pound nails tight For wide joist centers A 8 x 3 8 self tapping screw can be used ...

Page 4: ...t parts by PART NO not by KEY NO Lamp Bracket Assembly must be removed to service these parts FINISHED CEILING MATERIAL HOUSING COLLAR CLEARANCE HOLE 8 Finish ceiling Cut an opening in finished ceiling material for housing collar 9 Attach trim ring baffle to housing Remove the cardboard protector from inside the housing collar Use a pencil to insert one end of each spring into the holes on the lam...

Page 5: ...vant de le réinstaller Pour nettoyer l intérieur du boîtier Enlevez l anneau de garniture déflecteur et nettoyez l intérieur avec un aspirateur muni d une brosse souple FONCTIONNEMENT Le ventilateur et l éclairage peuvent être commandés par diverses combinaisons d interrupteurs et de commandes Le ventilateur et l éclairage commandés par un seul interrupteur Le ventilateur et l éclairage commandés ...

Page 6: ...es rainures du boîtier Courbez les onglets du protecteur en carton et insérez le dans l ouverture du boîtier REMARQUE Le protecteur en carton protège l intérieur du boîtier de la poussière de plâtre et de construction Ne l enlevez pas tant que la construction n est pas terminée PROTECTEUR EN CARTON Les conduits allant de ce ventilateur jusqu à l extérieur de l habitation ont une grande influence s...

Page 7: ... NOIR DESSUS ARRIÈRE DU BOÎTIER CÂBLE D ALIMENTATION À 2 FILS PLUS UN FIL DE TERRE MISE À LA TERRE SUR LA PLAQUE DE CÂBLAGE 3 Plantez les clous Enlevez temporairement l unité et enfoncez partiellement un clou sur chacune des quatre marques tracées 4 Suspendez et fixez le boîtier Suspendez l unité aux clous Vérifiez qu il y a bien un écart de 3 mm 1 8 po entre le bas du boîtier et le matériau du pl...

Page 8: ...t d éclairage doit être enlevé pour accéder à ces pièces 9 Fixez l anneau de garniture déflecteur au boîtier Enlevez le protecteur en carton à l intérieur du collet du boîtier À l aide d un crayon insérez une extrémité de chaque ressort dans les trous du support d éclairage Centrez l anneau de garniture déflecteur dans l ouverture du plafond 10 Installez l ampoule MATÉRIAU DU PLAFOND FINI COLLET D...

Page 9: ...ave Séquelo muy bien antes de volver a instalarlo Para limpiar el interior de la cubierta Saque el anillo deflector y aspire el interior de la cubierta con una aspiradora que tenga un cepillo suave como accesorio FUNCIONAMIENTO El ventilador y la lámpara pueden funcionar con varias combinaciones de interruptores de encendido apagado y controles Ventilador y lámpara controlados con un solo interrup...

Page 10: ... contra el rocío de yeso y el polvo de la construcción No lo quite hasta que la construcción esté completa PROTECTOR DE CARTÓN CUBIERTA SOPORTE DE MONTAJE VIGUETA DE TECHO CABLE ELÉCTRICO ANILLO DEFLECTOR TECHO ACABADO CONECTOR DEL REGULADOR DE TIRO CONDUCTO REDONDO DE 4 PULG 10 2 CM Y CONDUCTO REDONDO DE 4 PULG 10 2 CM Los conductos desde este ventilador hacia el exterior del edificio tienen un g...

Page 11: ...DE LA CUBIERTA CABLE ELÉCTRICO DE DOS HILOS Y CONEXIÓN A TIERRA TIERRA A PLACA DE CABLEADO 3 Martille los clavos Quite temporalmente la unidad y clave parcialmente los clavos en las vigas en los cuatro lugares marcados 4 Cuelgue la unidad y asegúrela Cuelgue la unidad en los clavos Compruebe para cerciorarse de que haya un 3 2 mm 1 8 po abra entre el fondo de la cubierta y el material del techo Cl...

Page 12: ...quitar el conjunto de soporte de la lámpara para dar ser vicio a estas piezas 9 Acople el anillo deflector a la cubierta Quite el protector de cartón del interior del collar de la cubierta Utilice un lápiz para insertar un extremo de cada resorte en los agujeros que están en el soporte de la lámpara Centre el anillo deflector en la abertura del techo 10 Instale la bombilla MATERIAL ACABADO DE TECH...

Reviews: