Opera ting instruction a nd documenta tion
UNI-LIFT 6500 - 8000
UNI LIFT 6500 - 8000
- 45 -
Version 1.0
• The air plug requires an air hose with diameter 0.24 inch, the operation pressure needs to be
6 to 10 bar.
• All cable ducts have to be equipped with protective coverings to prevent accidents.
9.2 Erection and doweling of the lift
• Erect power unit, plug air – and electricity connections
• Fill oil tank with oil: viscosity 32 cst, hold-up: approx. 10 litre
• connect hydraulic and pneumatic hoses and electrical cable between power unit and
automotive lift
• Push button “lift” at automotive lift until command side is lifted up high enough to touch the
ventilation screw. If this does not work, press override switch additionally until the lift reaches
the appropriate height.
• Open ventilation screw at command cylinder until oil leaks (Do not unscrew!)
• Close ventilation screw immediately and tighten.
• If the automotive lift needs to snap into ratchet before oil leaks from the ventilation screw, the
ventilation screw needs to be closed and the lift needs to be lifted once more marginally by
pushing the button “lift”. After that repeat procedure described earlier, until oil leaks.
• Perform balancing of rails as described in chapter 5.3.
• Lift up automotive lift to 60 inch.
• re-check placement of the first and second base plate
• Dowel power unit in floor.
• Setting of the lift, first each rail separately, then both rails together. Asynchronism needs to
be fixed by laying boards underneath the bearing.
• tighten Liebig-dowels with torque wrench (observe the regulation of the dowel manufacturer)
• Lift up and lower automotive lift, loaded with vehicle, several times, retighten dowels and
check hydraulic hoses for closeness.
• Bore holes to fix the dowels through the borings of the base plates. Clean holes with
pressure air. Put in safety dowels with washers in borings. The manufacturer
remommends LIEBIG safety dowels type or equal dowels of another manufacturer but
pay attention to their regulation.
• Before doweling check concrete floor with quality C20/25 if the concrete floor goes to the top
edge of the floor. In this case the dowels have to be chosen according to the picture on page
18. If the ground is covered with floor tiles, the dowels have to be chosen according to the
picture on page 23.
Summary of Contents for UNI-LIFT 6500
Page 12: ...Operating instruction and documentation UNI LIFT6500 8000 UNI LIFT 6500 8000 12 Version 1 0...
Page 13: ...Operating instruction and documentation UNI LIFT6500 8000 UNI LIFT 6500 8000 13 Version 1 0...
Page 14: ...Operating instruction and documentation UNI LIFT6500 8000 UNI LIFT 6500 8000 14 Version 1 0...
Page 15: ...Operating instruction and documentation UNI LIFT6500 8000 UNI LIFT 6500 8000 15 Version 1 0...
Page 17: ...Operating instruction and documentation UNI LIFT6500 8000 UNI LIFT 6500 8000 17 Version 1 0...
Page 18: ...Operating instruction and documentation UNI LIFT6500 8000 UNI LIFT 6500 8000 18 Version 1 0...
Page 19: ...Operating instruction and documentation UNI LIFT6500 8000 UNI LIFT 6500 8000 19 Version 1 0...
Page 20: ...Operating instruction and documentation UNI LIFT6500 8000 UNI LIFT 6500 8000 20 Version 1 0...
Page 21: ...Operating instruction and documentation UNI LIFT6500 8000 UNI LIFT 6500 8000 21 Version 1 0...
Page 25: ...Operating instruction and documentation UNI LIFT6500 8000 UNI LIFT 6500 8000 25 Version 1 0...
Page 26: ...Operating instruction and documentation UNI LIFT6500 8000 UNI LIFT 6500 8000 26 Version 1 0...
Page 27: ...Operating instruction and documentation UNI LIFT6500 8000 UNI LIFT 6500 8000 27 Version 1 0...
Page 28: ...Operating instruction and documentation UNI LIFT6500 8000 UNI LIFT 6500 8000 28 Version 1 0...
Page 29: ...Operating instruction and documentation UNI LIFT6500 8000 UNI LIFT 6500 8000 29 Version 1 0...
Page 30: ...Operating instruction and documentation UNI LIFT6500 8000 UNI LIFT 6500 8000 30 Version 1 0...