Operating Instruction and Documentation
SPL 4000
- 20 -
6 Troubleshooting
If the lift does not work properly, the reason might be quite simple. Please check
the lift for the potential reasons mentioned on the following pages. If the cause of trouble still
cannot be found, please call technical service.
Problem: Motor does not start!
Potential causes:
Repair failures:
No power supply
The main switch is not switch on
Defective fuse
The feed line is cut
Thermo fuse is active
Motor is defective
Top limit switch is pressed or defective
Check the power supply
Switch on the main switch
Change the fuse
Check it
Let it cool down
Call the technical service
Check top limit switch
Problem: Motor starts, lift does not lift!
Potential causes:
Repair failures:
The vehicle is too heavy
The oil level is too low
Defective hydraulic valve
Gear pump is defective
Leakage in the hydraulic system
Unload the vehicle
Refills
Call the technical service
Call the technical service
Check if leakage is present
Call the technical service
Problem: the lift does not lower!
Potential causes:
Repair failures:
An obstacle is restricting the lift from being lowered
Ball valve is defective
Button „lowering“ is defective
Press button „Lifting“ until the
obstacle is removed
Call the technical service
Check the button
Problem: the lift is lowering without handling!
Potential causes:
Repair failures:
Ball valve is defective
Call the technical service
6.1 Lowering onto an obstacle
If the carrying arms are lowered on an object, the lift stops the lowering process.
Press the button „lifting“ and raise the lift until the object can be removed.
Summary of Contents for SPL 4000
Page 9: ...Operating Instruction and Documentation SPL 4000 9 2 5 Attestation of conformity...
Page 11: ...Operating Instruction and Documentation SPL 4000 11 3 3 Data sheet 4090 mm with extension...
Page 12: ...Operating Instruction and Documentation SPL 4000 12 3 3 1 Data sheet 3650 mm...
Page 13: ...Operating Instruction and Documentation SPL 4000 13 3 4 Foundation diagram 200mm...
Page 16: ...Operating Instruction and Documentation SPL 4000 16...