Operating Instruction and Documentation
SPL 4000
- 28 -
Liebig-dowels
Dowel
type
BM12-20/80/40
Drilling
depth a 100
Min.
anchorage
depth
b 80
Thickness
of
concrete
c min.160
(*)
Diameter
of
bore d 20
Thickness
of
the
lift-pieces e 0-40
Number
of
dowels
12
Starting torque
70
(*) minimum thickness of concrete by using the mentioned dowels. Otherwise,
observe the regulation of the foundation plan.
You can use equivalent dowels from another dowel manufacturer (with license) but
observe their regulation.
Pic 5: choice of the dowel length with floor pavement or tile surface