43/46
9.2
Speed Chart for LIKgo Series
The maximum attainable traversing speed of the encoder is determined by the maximum
output frequency of the interpolator and/or the minimum counting frequency of the operator‘s
evaluation electronics (e.g. controller or display).
Please take the suitable values for your application from the following chart and select it in the
ordering key� Pay attention to your chosen interpolation factor and the targeted traversing speed
first. If you have found the respective information, please check if your evaluation electronics is
able to achieve the needed counting frequency�
The listed values in the charts refer to a grating period (TP) of 20 µm.
Speed factor
0
1
3
4
6
9
Interface
Interpolation factor
Max. traversing speed [m/s]
C
without interpolation (1 V
PP
)
10
–
K
Interpolation factor 1
–
0,83
1,66
1,66
3,3
6,6
L
Interpolation factor 5
0,66
1,66
1,66
3,3
6,6
M
Interpolation factor 10
0,33
1,33
1,66
3,3
6,6
I
Interpolation factor 25
0,13
0,53
1,06
1,66
3,3
N
Interpolation factor 50
0,07
0,27
0,53
1,06
1,66
V
Interpolation factor 64
0,05
0,21
0,41
0,83
1,66
Min� edge separation [ns]
500
1000
250
125
63
31
Min� counting frequency of the evaluation
electronics without 4-edge evaluation [MHz]
2
1
4
8
16
32
Speed factor
0
1
3
4
6
9
Chart 11