1 Flash with pause
Batteries voltage low
Batteries not been charged
Possible bad connection between batteries, controller
, charger or fuses
caused by loose connections , damaged wiring , water ingress
Not accepting charge due to faulty battery/cell
Charger not functioning
Operating time severely reduced or machine will not operate
Check when machine last charged
Switch OFF the machine : Remove Fuses Check connections to batteries, charger and fuses for loose wires or screws
Check each battery V
oltage individually to detect
defect unit 10.5V min
Check battery voltage and charge current ensuring charger red fault light is extinguished.
Charge batteries immediately
Tighten loose connections and replace damaged components
Replace batteries as required
Replace charger
Contact Service Agent
2 Flashes with pause
Traction motor disconnected
The motor has a bad connection
Motor disconnected
TCO activated (Thermal cut Out)
Motor failed open circuit
Motor will not operate
Check all connections and leads between the motor and controller
Tighten loose connections and replace damaged components.
3 Flashes with pause
Traction motor wiring Trip
The motor has a short circuit to a battery
Motor will not operate
Check all connections and leads between the motor and controller
4 Flashes with pause
Battery Lockout
The battery charge level has fallen below the battery lockout level and the controller is inhibiting machine functions
Machine functions not working
Check battery voltage and charge current ensuring charger red fault light is extinguished.
Check each battery V
oltage individually to detect
defect unit 10.5V min
Charge batteries immediately
6 Flashes with pause
Charger Connected
The controller is being inhibited from driving,
This may be because the
battery charger is connected
Machine functions not working
Remove Charger to operate machine
8 Flashes with pause
Controller
Trip
A controller trip is indicated
Machine functions not working
Check all connections and leads
Tighten loose connections and replace damaged components
9 Flashes with pause
Brake Deactivated or Failed.
Poor brake connections. Brake failure or deactivation.
Traction drive disabled.
Check brake wiring and brake lever
.
Replace brake or wiring as necessary
.
Reactivate brake by engaging brake lever
.
10 Flashes with pause
High Battery V
oltage
Poor connections between battery controller and traction motor
Machine functions not working
Check each battery V
oltage individually to ensure
voltage < 14 volts
Check connections on controller batteries and traction motor
Check combined battery pack voltage is < 28 volts
Green Status Indicator
Fault
Possible Cause
Ef
fect on Product
Investigate the Following
Action Required
If
fault
persists
Green Flashing W
arning light.
W
arning light flashes explained
Summary of Contents for TRO 650/200T