It is important to design the pipe runs so the hose is stored on one plane.
(figure 9).
Hose stored on two different planes. (figure 10).
Try to avoid back to back 90’s as
much as possible (figure 8).
figure 8
L
ow
V
oLtage
w
ire
Run low voltage wire to each inlet just as you would with a standard central
vacuum installation.
t
est
t
He
s
ystem
It is a good idea to test the system by retracting a hose before the walls are
sheet rocked. Since the inlet doors are needed to seal the system, hand balls
can be placed over each valve opening that is not being tested to seal the
system. In an up orientation, hand balls need to be taped in place.
Using a portable source of vacuum, check the system for sealed vacuum.
Sealed vacuum at the valve should not vary more than three to five inches
(12,7 cm) from the sealed vacuum at the power unit.
figure 9
figure 10
10