Plan the Installation 

3

Hose Lengths 

3

Power Unit Selection 

3

Valve Locations 

3

Plan Pipe Runs 

3

Rough In 

4

Determine Valve Height 

4

new Construction 

5

Pipe Runs 

6

Low Voltage Wire 

7

Test the System 

7

Trim Kit 

12

Installation in an existing Home 

14

notes 

15

Warning

This manual was designed for installers with working knowledge and 
experience installing traditional central vacuum systems.

It is critical that only parts designed for the retractable hose system 
be used in the installation.

Parts include: screws, seals, washers, hoses, elbows (90’s, 45’s), etc.

Failure to use these parts will void any warranty offered by the manu-
facturer.

Installers are responsible for adhering to all local building codes.

Plan THe InsTallaTIon

Planning is the key to a successful central vacuum system installation.  
A balance between the best locations for the inlet valves and practicality  
of these locations is essential. With a little ingenuity most locations can  
be reached.

H

ose

 L

engtHs

Let clients know that you will custom the hose length to fit each floor.  
Hose kits come in 30’ (9,1 m), 40’ (12,2 m) or 50’ (15,2 m) lengths.

P

ower

 U

nit

 s

eLection

It is important to keep in mind that air flow is reduced with longer hoses.  
To compensate for the loss of air flow, a more powerful unit is required.

V

aLVe

 L

ocations

A 50' (15,2 m) hose will usually cover between 1800-2300 square feet  
(167 to 213 m

2

). Inlets should, if possible, be located in a hallway or in other 

areas that do not have high visibility.

P

Lan

 P

iPe

 r

Uns

Carefully read the section in this guide on “Pipe Runs”. A diagram of four  
typical pipe runs is also available in this section.

14

figura 16

figura 17

figura 18

InsTalaCIón en una Casa ya 

exIsTenTe

Utilizar la placa temporaria como  
modelo para hacer el agujero en  
la pared (figura 16).

Insertar la placa de montaje verticalmente para 
hacerla girar hacia arriba (figura 17).

Independientemente de donde se sitúa el 2x4, 
tendrá que cortar uno o dos triángulos de fijación 
de la placa de montaje.

Insertar los 2 triángulos de fijación ubicados en  
la parte baja de la placa de montaje (figura 18). 
Para asegurar una mejor fijación, insertar los cla-
vos para fijar la toma con la contratoma 

Seguir las mismas instrucciones para instalar los conductos de PVC y la 
toma. 

Summary of Contents for HUSKY Hide-A-Hose

Page 1: ...HIDE A HOSE R TRAFLEX Syst me de boyau r tractable au mur...

Page 2: ...ation in an existing Home 14 FRAN AIS Plani cation de l installation 15 Les longueurs de boyau 15 Choix de l unit d aspiration 15 Emplacement des prises 15 Parcours des conduits 15 Plan initial 16 D t...

Page 3: ...s for the inlet valves and practicality of these locations is essential With a little ingenuity most locations can be reached Hose LengtHs Let clients know that you will custom the hose length to fit...

Page 4: ...ight Top of valve inlet should be aligned with top of light switches to make sure hose can easily be pulled out In a down orientation tubing is being run in the crawl space align the bottom of the val...

Page 5: ...pe fitting is designed to slide in the frame and adjust for variations in wall board thickness figure 3 The maximum wall thickness the valve can work with is 1 9 cm Install the pipe into the fitting f...

Page 6: ...bing To prevent this be sure to always glue the pipe and not the fittings Make sure to remove all burrs from the pipe ends that were cut Carefully inspect the pipe to make sure the inside is smooth an...

Page 7: ...ood idea to test the system by retracting a hose before the walls are sheet rocked Since the inlet doors are needed to seal the system hand balls can be placed over each valve opening that is not bein...

Page 8: ...8 8 Down Orientation Up orientation Hose is stored on the same plane Hose ends Hose is stored on the same plane Hose ends...

Page 9: ...9 9 Down two floors Up two floors Hose is stored on the same plane Try to limit the number of 90 s Hose ends Hose is stored on the same plane Hose ends Up two floors needs a strong power unit...

Page 10: ...umber of 90 s 2 Down Orientation Only fittings designed for the retrac table hose system 90 s 45 s and 22 5 s can be used in the section of pipe that stores the hose 3 Up Orientation It is important t...

Page 11: ...install at least 44 13 4 m of pipe before connecting to another pipe run Hose is stored in the tubing 4 Up two floors Needs a strong power unit In order to ensure enough pipe to store the hose the pip...

Page 12: ...kely that these tabs were cut off by the sheet rock installers It might be helpful to push small finish nails horizontally into the sheet rock through the holes in the side of the frame TRIm KIT Trim...

Page 13: ...rough in frame figure 13 figure 13 Align the four holes in the valve assembly with the holes in frame figure 14 Secure with the fours screws included with the trim kit A 5 8 14 7 cm B 8 20 3 cm Instal...

Page 14: ...may need to score and cut off one or both of the mounting tabs Push the bottom two pointed tabs into the sheet rock figure 18 The top pointed tab can be bent down as you pull the top of the frame into...

Page 15: ...ent des prises et l accessibilit de celles ci est essen tielle Avec un peu d ing niosit on peut atteindre tous les acc s Les Longueurs de boyau Informer le consommateur que vous ajusterez la longueur...

Page 16: ...alement la prise est plus facile d utilisation lorsqu elle est la hauteur d un interrupteur de lumi re orient e vers le bas la sortie du boyau vers le plancher la base de la prise devrait tre la m me...

Page 17: ...con u pour glisser l int rieur de la plaque de montage figure 3 et s ajuster aux diverses paisseurs des murs Le raccord peut tre utilis jusqu une paisseur murale maximale de 1 9 cm Installer le condu...

Page 18: ...ur les tuyaux de PVC et non sur les coudes S assurer d enlever tous les filaments des tuyaux de pvc une fois taill s Inspecter soigneusement les tuyaux pour s assurer que l int rieur est lisse bien ro...

Page 19: ...avant de fermer les murs Avant la pose des portes de prises qui fermeront herm tiquement l installation une balle peut tre plac e chaque ouverture de prise pour v rification de l tan ch it du syst me...

Page 20: ...20 8 orientation vers le bas orientation vers le haut Le boyau est emma gasin sur un seul niveau Fin du boyau Le boyau est emma gasin sur un seul niveau Fin du boyau...

Page 21: ...sur deux tages vers le haut Le boyau est emma gasin sur un seul niveau Essayez de limiter le nombre de coudes 90 Fin du boyau Le boyau est emmaga sin sur un seul niveau Fin du boyau Hisser un boyau su...

Page 22: ...tion vers le bas Seulement les coudes rayon allong con us sp cialement pour un tel syst me peuvent tre utilis s dans l espace o le boyau se r tracte coudes 90 45 et 22 5 3 orientation vers le haut Il...

Page 23: ...13 4 m de PVC avant de raccorder la ligne Le boyau se r tracte dans les conduits 4 installation sur deux tages vers le haut N cessite un aspirateur central plus puissant Pour s assurer d avoir assez d...

Page 24: ...r des murs de finition Si tel est le cas ou simplement pour mieux fixer le tout de petits clous de fini tion peuvent tre ins r s horizontale ment dans le biais du mur de finition eNsemble de fiNiTioN...

Page 25: ...de montage figure 13 figure 13 figure 14 figure 15 Aligner les quatre trous de la prise assem bl e avec les trous de la plaque de mon tage figure 14 Fixer avec les quatre vis incluses dans le kit de...

Page 26: ...nt du montant 2x4 enlever soit une ou les deux lamelles de fixation de la plaque de montage Ins rer les deux ancrages situ s au bas de la plaque de montage dans le biais du mur figure 18 L ancrage du...

Page 27: ...Notes...

Page 28: ...traflex Distributed by Distribu par Nuera Air 1490 Dagenais Blvd W 1490 boul Dagenais Ouest Laval Qu bec H7L 5C7 CANADA Tel 1 450 622 9000 Fax 1 450 622 7712 info nuera air com www nuera air com DOC 5...

Reviews: