background image

14

14

InsTallaTIon In exIsTIng Home

figure 16

figure 17

figure 18

Use the mud cover as a template to cut 
the hole (figure 16).

Insert the rough in frame vertically, then turn it 
back upright behind the wall (figure 17).

Depending on how close you are to a stud (2x4), 
you may need to score and cut off one or both of 
the mounting tabs.

Push the bottom two pointed tabs into the sheet 
rock (figure 18). The top pointed tab can be bent 
down as you pull the top of the frame into the 
hole. The tabs will help hold the frame into place 
while you install the valve. You may need to push 
a couple of small finish nails horizontally into the 
holes located on the side of the frame.

Follow the same instructions for installing the pipe runs and trim.

3

Atención

Este manual supone que el instalador tenga la formación adecuada 
y la experiencia necesaria para hacer la Instalación de un sistema 
de aspiración centralizada.

Es muy importante solo utilizar los componentes del fabricante Hide 
a Hose Inc. para hacer una instalación. Los componentes incluyen 
tornillos, juntas de estanqueidad, arandela de fijación, manguera, 
codos de 90°, codos de 45°, etc.… Al no respetar el uso de estos 
componentes se puede anular la garantía del fabricante.

El instalador tiene la responsabilidad de conformarse a todos los 
reglamentos del sector de la construcción.

PlanIfICaCIón de la InsTalaCIón

La planificación es la clave de una instalación bien hecha. El equilibrio entre 
la mejor ubicación de las tomas y el acceso de estas es esencial. Se puede 
con un poco de ingeniosidad alcanzar todos los accesos.

L

ongitud

 

de

 

La

 

manguera

Informar el cliente que puede elegir una longitud de manguera diferente 
según las dimensiones de cada planta. Se puede utilizar mangueras de 
30’ (9.1m), 40’ (12.2m), o 50’ (15.2m).

e

Lección

 

de

 

un

 

aspirador

Es importante saber que cuanto más larga sea la manguera, el caudal de 
aire disminuirá. Para compensar esta perdición, hay que elegir un aspirador 
más potente.

u

bicación

 

de

 

Las

 

tomas

La manguera de 50’ (15.2m) cubrirá entre 167 a 213 m

2

. La toma se ubica 

más bien en un vestíbulo o en cualquier otro sitio escondido.

i

mpLantación

 

de

 

Los

 

tubos

Leer atentamente la parte de este guía sobre “la implantación de los tubos”. 
Encontrara también un diagrama para un ejemplo de 4 instalaciones.

Summary of Contents for HUSKY Hide-A-Hose

Page 1: ...HIDE A HOSE R TRAFLEX Syst me de boyau r tractable au mur...

Page 2: ...ation in an existing Home 14 FRAN AIS Plani cation de l installation 15 Les longueurs de boyau 15 Choix de l unit d aspiration 15 Emplacement des prises 15 Parcours des conduits 15 Plan initial 16 D t...

Page 3: ...s for the inlet valves and practicality of these locations is essential With a little ingenuity most locations can be reached Hose LengtHs Let clients know that you will custom the hose length to fit...

Page 4: ...ight Top of valve inlet should be aligned with top of light switches to make sure hose can easily be pulled out In a down orientation tubing is being run in the crawl space align the bottom of the val...

Page 5: ...pe fitting is designed to slide in the frame and adjust for variations in wall board thickness figure 3 The maximum wall thickness the valve can work with is 1 9 cm Install the pipe into the fitting f...

Page 6: ...bing To prevent this be sure to always glue the pipe and not the fittings Make sure to remove all burrs from the pipe ends that were cut Carefully inspect the pipe to make sure the inside is smooth an...

Page 7: ...ood idea to test the system by retracting a hose before the walls are sheet rocked Since the inlet doors are needed to seal the system hand balls can be placed over each valve opening that is not bein...

Page 8: ...8 8 Down Orientation Up orientation Hose is stored on the same plane Hose ends Hose is stored on the same plane Hose ends...

Page 9: ...9 9 Down two floors Up two floors Hose is stored on the same plane Try to limit the number of 90 s Hose ends Hose is stored on the same plane Hose ends Up two floors needs a strong power unit...

Page 10: ...umber of 90 s 2 Down Orientation Only fittings designed for the retrac table hose system 90 s 45 s and 22 5 s can be used in the section of pipe that stores the hose 3 Up Orientation It is important t...

Page 11: ...install at least 44 13 4 m of pipe before connecting to another pipe run Hose is stored in the tubing 4 Up two floors Needs a strong power unit In order to ensure enough pipe to store the hose the pip...

Page 12: ...kely that these tabs were cut off by the sheet rock installers It might be helpful to push small finish nails horizontally into the sheet rock through the holes in the side of the frame TRIm KIT Trim...

Page 13: ...rough in frame figure 13 figure 13 Align the four holes in the valve assembly with the holes in frame figure 14 Secure with the fours screws included with the trim kit A 5 8 14 7 cm B 8 20 3 cm Instal...

Page 14: ...may need to score and cut off one or both of the mounting tabs Push the bottom two pointed tabs into the sheet rock figure 18 The top pointed tab can be bent down as you pull the top of the frame into...

Page 15: ...ent des prises et l accessibilit de celles ci est essen tielle Avec un peu d ing niosit on peut atteindre tous les acc s Les Longueurs de boyau Informer le consommateur que vous ajusterez la longueur...

Page 16: ...alement la prise est plus facile d utilisation lorsqu elle est la hauteur d un interrupteur de lumi re orient e vers le bas la sortie du boyau vers le plancher la base de la prise devrait tre la m me...

Page 17: ...con u pour glisser l int rieur de la plaque de montage figure 3 et s ajuster aux diverses paisseurs des murs Le raccord peut tre utilis jusqu une paisseur murale maximale de 1 9 cm Installer le condu...

Page 18: ...ur les tuyaux de PVC et non sur les coudes S assurer d enlever tous les filaments des tuyaux de pvc une fois taill s Inspecter soigneusement les tuyaux pour s assurer que l int rieur est lisse bien ro...

Page 19: ...avant de fermer les murs Avant la pose des portes de prises qui fermeront herm tiquement l installation une balle peut tre plac e chaque ouverture de prise pour v rification de l tan ch it du syst me...

Page 20: ...20 8 orientation vers le bas orientation vers le haut Le boyau est emma gasin sur un seul niveau Fin du boyau Le boyau est emma gasin sur un seul niveau Fin du boyau...

Page 21: ...sur deux tages vers le haut Le boyau est emma gasin sur un seul niveau Essayez de limiter le nombre de coudes 90 Fin du boyau Le boyau est emmaga sin sur un seul niveau Fin du boyau Hisser un boyau su...

Page 22: ...tion vers le bas Seulement les coudes rayon allong con us sp cialement pour un tel syst me peuvent tre utilis s dans l espace o le boyau se r tracte coudes 90 45 et 22 5 3 orientation vers le haut Il...

Page 23: ...13 4 m de PVC avant de raccorder la ligne Le boyau se r tracte dans les conduits 4 installation sur deux tages vers le haut N cessite un aspirateur central plus puissant Pour s assurer d avoir assez d...

Page 24: ...r des murs de finition Si tel est le cas ou simplement pour mieux fixer le tout de petits clous de fini tion peuvent tre ins r s horizontale ment dans le biais du mur de finition eNsemble de fiNiTioN...

Page 25: ...de montage figure 13 figure 13 figure 14 figure 15 Aligner les quatre trous de la prise assem bl e avec les trous de la plaque de mon tage figure 14 Fixer avec les quatre vis incluses dans le kit de...

Page 26: ...nt du montant 2x4 enlever soit une ou les deux lamelles de fixation de la plaque de montage Ins rer les deux ancrages situ s au bas de la plaque de montage dans le biais du mur figure 18 L ancrage du...

Page 27: ...Notes...

Page 28: ...traflex Distributed by Distribu par Nuera Air 1490 Dagenais Blvd W 1490 boul Dagenais Ouest Laval Qu bec H7L 5C7 CANADA Tel 1 450 622 9000 Fax 1 450 622 7712 info nuera air com www nuera air com DOC 5...

Reviews: