![NuDAQ ACL-8112 Series User Manual Download Page 35](http://html1.mh-extra.com/html/nudaq/acl-8112-series/acl-8112-series_user-manual_1716414035.webp)
Signal Connections
•
27
It is very suitable for the simple applications that do not need complex
signal condition before the A/D conversion is performed.
3.6.5 Connect with ACLD-9182
The ACLD-9182 is a 16 channel isolated digital input board. This board
is connected with CN1 of ACL-8112 via 20-pin flat cable. The advantage
of board is an 500Vdc isolation voltage is provided, and it can protect your
PC system from damage when an abnormal input signal is occurred.
3.6.6 Connect with ACLD-9185
The ACLD-9185 is a 16 channel SPDT relay output board. This board is
connected with CN2 of ACL-8112 via 20-pin flat cable. by using this board,
you can control outside device through the digital output signals.
3.6.7 Connect with ACLD-9188
ACLD-9188 is a general purpose terminal board for all the card which
comes equipped with 37-pin D-sub connector.