Installation
•
19
The internal voltage is -5V or -10V which can is selected by JP1 of ACL-
8112DG/HG or JP8 of ACL-8112PG. The possible configurations are
specified as Figure 2.9. Note that the internal reference voltage is used
only when the JP2 of ACL-8112DG/HG or JP6 nd JP7 of ACL-8112PG is
set to internal reference.
Reference Voltage is
-5V (default setting)
JP1 /
JP8
-10V
-5V
Reference Voltage is
-10V
JP1 /
JP8
-10V
-5V
Figure 2.9 Internal Reference Voltage Setting
2.12 A/D Input Range Setting
(This section is for ACL-8112PG only)
The A/D input range of ACL-8112PG can be set to
±
5V or
±
10V by jumper
JP9.
Summary of Contents for ACL-8112 Series
Page 1: ...NuDAQ ACL 8112 Series Enhanced Multi Functions Data Acquisition Cards User s Guide ...
Page 4: ......
Page 40: ...32 Registers Format 1 1 1 1 1 000 Unipolar N A Table 4 2 1 Function of the Gain Control Bits ...
Page 44: ...36 Registers Format Base 14 DO15 DO14 DO13 DO12 DO11 DO10 DO9 DO8 ...
Page 46: ...38 Registers Format Base 2 Counter 2 Register R W Base 3 8254 CONTROL BYTE ...
Page 71: ...C Language Library 63 ...
Page 81: ...C Language Library 73 Example See Demo Program AD_Demo4 C ...
Page 85: ...C Language Library 77 ERR_AD_INTNotSet Example See demo program AD_Demo2 C ...