17

 

• The voltage should be within 13.8 and 14.0 volts. 
(The meter of the tester should be calibrated 
periodically.)  

• If converter is not within these voltages, have it 
serviced by a qualified technician or replace it.  

A label on the inside of the converter door lists the 
circuits and what each fuse powers. 

Converter Operation 

 

The electronic power converter is designed to 
supply the nominal 12-volt-filtered DC power for 
all 12-volt operated devices encountered in RV 
service. Although the converter is an excellent 
battery charger, the converter does not require a 
battery to be connected to it for proper operation.

 

NOTE 

When installing a battery (s), always observe 

polarity. Connecting a battery in reverse polarity 

will blow the power converter main fuses located 

on the 12-volt DC distribution fuse block 

120-Volt AC Panel Board  

The AC panel board section contains the 120 VAC 
branch circuit breakers for your RV. One of the 
breakers controls the 120-volt power to the 12-volt 
converter section. This breaker may also control 
another branch circuit. Check the label next to each 
breaker for what each branch circuit breaker 
controls.  

The 120-volt circuits may be turned on by setting 
their breaker handle up, to the ON position, or off 
by setting the handle down, to the OFF position. To 
reset the tripped breaker, move handle to OFF then 
ON.  

The system incorporates GFCI breakers that 
implement an auto self-test functionality. When 
turned off, these breakers require external AC 
power to be present, or the AC inverter enabled, 
before they can be turned back on. If AC power is 
present from one of these two sources, and the 
breaker refuses to stay on consult an electrician or 
certified RV technician.  

Fuses and Breakers  

Breakers  

The distribution panel was 
designed to use a 30 Amp 
120Volt main breaker with 
branch circuits. Double 

breakers may be used for the branch circuits. 
Should a breaker become faulty replace with the 
same type breaker only. Use only approved circuit 
breakers and 12V fuses.  

NOTE 

When replacing circuit & breakers replace with 

the same type and rating as the original. 

 12 VDC Fuses  

Each 12 VDC circuit in the 
distribution panel was 
designed for a maximum of 
a 20-amp automotive style 
fuse. Should one need to be 

replaced, be sure to replace it with the same type 
and Amp rating as originally supplied by nüCamp 
RV. Replacing it with either a higher or lower Amp 
fuse could result in the panel not functioning 
properly.  

Reverse Polarity Fuses 

 The power converter is equipped with reverse 
polarity fuses, should these fuses “blow” either 
during the manufacturing process or while 
connecting the battery, replace with the same type 
and rating fuse as originally provided with the 
equipment.  

The power converter is not weather resistant nor 
designed for installation in wet locations. The 
power converter must be protected from direct 
contact with water. 

120-Volt Electrical System 

Shore Power  

When your trailer is hooked up to 
external AC power, the converter 
system automatically charges the 

Summary of Contents for T@B 320

Page 1: ...T B 320 MANUAL...

Page 2: ...latest product information available at the time of publication approval When new materials and production techniques are developed that can improve the quality of its product or material substitutio...

Page 3: ...___________________________________________________________________ ___________________________________________________________________ _______________________________________________________________...

Page 4: ...Towing and Weight Distribution 6 Control Sway 6 Reporting Safety Defects 6 Camping Pre Travel Check List 7 Alarms and Detectors 7 Important Safety Precautions 8 Fire Extinguisher 10 Chemical Sensitivi...

Page 5: ...ion 27 Exterior Shower 29 Waste System 30 Waste Water Holding Tanks 30 Toilet 30 Water System Maintenance and Troubleshooting 32 L P Gas 33 Fill Valve 33 Propane Regulator 34 Basic Rules for LPG Safet...

Page 6: ...ge Hood Error Bookmark not defined Refrigerator 41 Alde System 41 Drains 41 Shower Care 41 Sink Care 41 Storage Tips 42 Winter Precautions 42 Care and Maintenance Chart 43 Maintenance Schedule 44 Wint...

Page 7: ...nual to be more detailed All information illustrations and specifications contained in this manual are based on the latest product information available at the time of publication approval If new mate...

Page 8: ...proper maintenance As the owner you have the responsibility to properly maintain your camper Be sure you have service performed in a timely manner Don t ignore a problem sometimes a phone call is all...

Page 9: ...anufacturers owner s manuals provided with your RV and file appropriate individual warranty cards as required You have joined an elite group and as you begin making great memories using your new n Cam...

Page 10: ...by in whole or in part or in any way related to Accidents misuse including off road use or negligence Failure to comply with the instructions set forth in any owner s manual provided with the camper A...

Page 11: ...ler or may request that you bring your camper to the n Camp RV factory in Sugarcreek Ohio for repairs n Camp RV does not control the scheduling of repairs at its authorized n Camp RV dealers and repai...

Page 12: ...elow Tire Safety Properly maintained tires improve stopping traction and load carrying capability of your vehicle Also be sure to read the Tire Safety Manual included with your owner s packet Towing a...

Page 13: ...Emergency road warning triangle 10 First aid kit Alarms and Detectors Smoke Alarm A smoke detector is provided with your trailer A manual pertaining to the detector is included in the paper work give...

Page 14: ...esent in other areas Important Safety Precautions Carbon monoxide is produced by the incomplete combustion of fuels such as wood charcoal coal heating oil paraffin gasoline natural gas propane butane...

Page 15: ...ed use of un vented fuel burning devices 3 Temperature increase that can trap exhaust gases near the ground Symptoms of Carbon Monoxide Poisoning The following symptoms are related to CO POISONING Mil...

Page 16: ...variety of asthma like symptoms Elderly persons and young children as well as anyone with a history of asthma allergies or lung problems may be more susceptible to the effects of off gassing Formaldeh...

Page 17: ...springs it will provide some stability If you must park on a slope park facing downhill It is easier to level the trailer this way Before moving on check your campsite both for cleanliness and to be...

Page 18: ...that a family of four can vaporize up to three gallons of water daily through breathing cooking bathing and washing Unless the water vapor is carried outside by ventilation or condensed by a dehumidi...

Page 19: ...water leaks Proper preventive maintenance to the trailer and its accessories as described both in this manual and in accompanying literature will provide the best protection to the camper For more inf...

Page 20: ...__________________________________________________________ __________________________________________________________________________________________ __________________________________________________...

Page 21: ...ay damage the flooring In most cases a clean damp cloth or mop will suffice to clean dirty flooring When necessary a solution of mild detergent or domestic floor cleaning emulsion can be used to clean...

Page 22: ...ribution panel will still receive power from the converter but the batteries are disconnected from the system The batteries will not be drained with the switch in the OFF position The converter will n...

Page 23: ...elf test functionality When turned off these breakers require external AC power to be present or the AC inverter enabled before they can be turned back on If AC power is present from one of these two...

Page 24: ...on self contained battery power or hooked up to 120 volt city power The 12 volt light bulbs give off the same light as regular household bulbs so that when operating on self contained battery power ev...

Page 25: ...ins on when the Test button is pushed the GFCI is not working properly or has been incorrectly installed wired wrong If your GFCI is not working properly call a qualified certified electrician who can...

Page 26: ...amage and is necessary during low voltage conditions This breaker tripping is sometimes perceived as a fault in your camper but it is a necessary safety valve NOTE Review the air conditioning literatu...

Page 27: ...g periods of time Never use portable fuel burning equipment including wood and charcoal grills and stoves inside the vehicle because a fire or explosion may result WARNING Do not turn the oven or burn...

Page 28: ...igerator is on If the refrigerator doesn t light or stay on contact your Dealer or Norcold The battery must have a decent charge before you can start the refrigerator on propane mode NOTE Do not trave...

Page 29: ...winterize the camper but instead used air to blow out the system then there is nothing you need to do to use the Alde heater for heat If you did use RV anti freeze to winterize you will need to open t...

Page 30: ...e breaker for that outlet is on For more troubleshooting tips see page 8 in the Alde manual Turn on the water pump and open hot water at the kitchen sink and at the shower when water flows continuousl...

Page 31: ...ances If the water heater will be out of service for some time it should be drained See Storage chapter for more information When using hot water faucets in the camper for the first time after heating...

Page 32: ...ed Turn the pump ON to pressurize the water system When the faucet is opened the water may sputter for a few seconds This is normal and no cause for alarm The water flow will become steady when all ai...

Page 33: ...flows evenly and no air bubbles are evident 6 Top off water tank through the exterior fill spout to replace water used in filling the water heater and purging the water lines of air 7 Close cap and l...

Page 34: ...e sure to open faucets water heater drains and system low point drains to remove all fresh water from the system Be sure the water pump is turned OFF NOTE When leaving the camper for extended periods...

Page 35: ...supply The water in the hand held shower hose will drain through this vacuum breaker when the faucet is turned OFF This is not a leak This drainage is inherent in the design of the vacuum breaker and...

Page 36: ...from the sinks and tubs and a black water system which includes the holding tank and drain for toilet wastes Each system is self contained and allows disposal of waste water at designated dump statio...

Page 37: ...he holding tanks 1 Attach the sewer hose to the dump outlet 2 Extend the hose and insert the hose end into the sewer or dump station inlet pushing it firmly into the opening to be secure In some cases...

Page 38: ...use motorized drain augers Sometimes the holding tank valve will get clogged In this case a hand operated auger may be necessary Be ready to close the valve quickly once the clog is cleared If the sea...

Page 39: ...anded threads on its interior This feature allows for connection of the new wrench less right handed Acme RV connection while still accommodating the standard left handed POL fittings used for filling...

Page 40: ...o avoid potential problems have your propane system checked at least once a year by an authorized service center after each extended trip NEVER test for a leak by lighting a match or having an open fl...

Page 41: ...en located near the LPG container This label reads DO NOT FILL CONTAINER S TO MORE THAN 80 PERCENT OF CAPACITY Overfilling the LPG container can result in uncontrolled gas flow which can cause fire or...

Page 42: ...__________________________ _____________________________________________________________________________ _____________________________________________________________________________ _________________...

Page 43: ...or surfaces Wash your camper in a shady area not in direct sunlight If the camper is parked in the sun move it into the shade and let the exterior cool down before you start Chemical solvents and stro...

Page 44: ...h mineral spirits Make sure that all areas to be resealed are dry before new sealant is applied Mineral spirits are a flammable liquid Use extreme care when handling Do not expose to open flame sparks...

Page 45: ...use a high pressure spray nozzle when rinsing your windows skylight vent after washing Avoid washing windows skylight vent in direct sunlight Freezing Weather Vinyl seals around windows and doors sho...

Page 46: ...ctrical terminal connections with non conducting dielectric light waterproof grease Clean the prongs with very fine sandpaper being careful not to damage the contact area Battery s Your camper is outf...

Page 47: ...e surface Refrigerator Clean interior with mild soap and water after each trip Defrost freezer and empty ice trays When defrosting place dry towels in the refrigerator to absorb the water Place trays...

Page 48: ...iance vents to prevent moisture and insects from entering during storage 7 Check the interior of the camper periodically to be sure leaks have not developed or that condensation has not formed causing...

Page 49: ...Frame Inspect and touch up paint as needed Hitch Coupler Verify proper operation and free of damage Hitch Jack Verify proper operation and free of damage Interior Surfaces Clean as needed Lug Nut Torq...

Page 50: ...44 Maintenance Schedule Date Maintenance Repair Schedule Service Center Name Address...

Page 51: ...ly open 1 4 a roof vent 9 Close and lock all windows Be sure the vent fan and range hood fan switches are off 10 Cap and close the holding tank drain city water inlet and fresh water fill spout 11 Tur...

Page 52: ...e water coming out of the pump Now open all Faucets and Shower valves to allow water to drain from the system After the water has stopped coming out of the drain valves shown in page 2 and 3 you can a...

Page 53: ...47 Clamshell T B Valves are in camping season mode Valves are in winterizing mode after water was drained from the lines only needed if you re using RV antifreeze to winterize...

Page 54: ...compressor hose KEEP THE PRESSURE WELL BELOW 50psi To find this part search Blow out plug on Amazon Here is what you can use to put antifreeze into the city water line it has a hose connection on the...

Page 55: ...Fresh water tank fill port Located in front of the Passenger side wheel Valves are in winterizing mode after water was drained from the lines only needed if you re using RV antifreeze to winterize Val...

Page 56: ...50...

Page 57: ...e http www asaelectronics com customerservice 4 Hot Water Heat Alde phone 360 608 4803 http www alde se us support alde service locations or info alde us 5 Batteries Dealer Provided contact your deale...

Reviews: