Scanning Graphics into OmniForm Filler
Technical Information 5
Scanning Graphics into OmniForm Filler
This section describes common scanning problems that may occur if you
use a scanner to import a graphic into a fill graphic field:
• System Hang During Scan
• Scanner Compatibility
System Hang During Scan
A system hang during a scan could have several possible causes:
• An interrupt conflict between your scanner and another device
such as a bus mouse or network card.
Check interrupt addresses for a possible conflict. See your device
documentation.
• A SCSI termination problem.
Make sure the scanner is terminated properly. See your scanner
documentation.
• A memory-related problem.
Try closing open windows and applications to free up memory.
Scanner Compatibility
If you experience a problem between OmniForm Filler and your
scanner, make sure your scanner is a TWAIN-compatible scanner, such
as Canon, Epson, or Microtek.
Select setup options for TWAIN-compliant scanners in the TWAIN
dialog box that appears before scanning. Select 200, 300, or 400 dots per
inch (dpi) for the resolution. Select line art, bi-tone, or black-and-white
line drawing for the image type. OmniForm Filler cannot process
grayscale or color scans.