background image

Smart ‘S’  

TWINFAN CONTROL

Installation and Maintenance   

4

1        2         3        4        5        6        7        8  

ON

OFF

1        2         3        4        5        6        7        8  

ON

OFF

1        2         3        4        5        6        7        8  

ON

OFF

1        2         3        4        5        6        7        8  

ON

OFF

1        2         3        4        5        6        7        8  

ON

OFF

30% TRICKLE SPEED

40% TRICKLE SPEED

50% TRICKLE SPEED

NO TRICKLE SPEED

AIRFLOW DIRECTION 
BOX FITTED

Smart Twinfan DIL switch settings
(see fig 2).

The Smart Twins operation can be individually tailored to suit
your own particular application.

A label is attached to the inside of the control module cover
detailing the various switch functions.

Refer also to switch settings shown opposite.

DEFAULT MODE: 
The fan runs in trickle mode until the toilet is occupied

Switch 1 & Switch 2 ..........Trickle mode and rate

Switch 3    .............................2  way Damper Box fitted

ON = Damper Box fitted (split duty system)
OFF = No Damper Box fitted

Adding Sensors & Controls

Refer to page 2 of this leaflet for a list of sensors and user 

controls which are available for use with the Smart controlled

Quietwin fans.

Sensors and user controls etc are supplied complete with specif-

ic installation details.

Additional general sales information on these optional ancillaries

is shown in the NuAire ‘TWINFANS’ Sales / Technical

brochure (Leaflet No 670808) available on request from the

NuAire Technical Library Tel: 01222 858231.

QTE & QTR external use Quietwins
with SMART ‘S’ control option.

The essential control difference with these fans is that they
have the main control module inside the fan case. 
A small commissioning box is provided on the outside of
the case which contains the essential commissioning control
buttons i.e. The ‘STEP’ button and the run on and speed
adjustment controls.  Figure 5 shows a typical QTR
Quietwin and the details of the customers commissioning
box.
Commissioning procedure is the same as that shown on
page 3 for the internal use units.

Mains Supply

Mains Supply
and Sensor(s) to
Control Module
inside fan.

Commissioning 
box on outside 
of case ('S' control
external use unit only).

P.I.R. Sensor

Fig. 5.  Exterior commissioning control box panel.

Step button

Fan 1

Fan 2

OFF

AUTO

Speed

Run on

Step Button 
manually
steps through 
functions

These controls
located inside 
commissioning box
(External use
'S' control option 
units only)

Speed 
Adjustment

Run on
Adjustment

(see commissioning procedure)