2

nuaire.co.uk 

029 2085 8400

19. 02. 19. Document Number  671881

Installation Manual

NOXMASTER - PIV with Carbon Filtration

This appliance should not be used by children or persons with reduced physical, sensory or 

mental capabilities or lack of experience and knowledge, unless they have been given supervision 

or instruction concerning the safe use of the appliance by a person responsible for their safety. 

Children shall not play with the appliance. Cleaning and user maintenance shall not be carried out 

by children.

or instruction concerning use of the appliance in a safe way and 
understand the hazards involved. Children shall not play with the 
appliance. Cleaning and user maintenance shall not be carried out by 
children without supervision.

Precautions must be taken to avoid the back-flow of gases into the 
room from the open flue of gas or other fuel-burning appliances. 

Means for disconnection must be incorporated in the fixed wiring as 
shown in the wiring diagram in accordance with IEE wiring or national 
wiring rules.

CAUTION: In order to avoid a hazard due to inadvertent resetting of 
the thermal cut-out, this appliance must not be supplied through an 
external switching device, such as a timer, or connected to a circuit that 
is regularly switched on and off by the utility.

4.1 Loft Inspection

Ensure

 that the loft has adequate ventilation. There may be occasions 

where a loft is so well sealed that additional ventilation may have to be 
provided by the owner/occupier. 

Ensure

 that all water tanks are covered and sealed. 

Check 

that all water pipes are lagged. 

Check

 the area of the installation that beams are flat and level and are 

capable of supporting the total weight of the unit. 

Ensure

 the insulation is not proud of the beams. If insulation is prouder 

than the beams, alternative arrangements to provide a flat surface 
above the insulation may be required. Do not install the unit with 
insulation contacting the underside of the unit.      

Ensure

 that extract fans are discharging to outside, not into the loft. 

Check 

that the loft hatch is tightly sealed. 

Ensure 

that all ceiling holes are sealed i.e. ceiling light fittings etc. A 

visual inspection of any flues or chimneys for leakage in the loft should 
be carried out by the installer.  

If any

 leakage points are found, or if there is any doubt at all, then the 

installer should advise the house owner/provider as soon as possible 
and seek instruction from them before proceeding with the installation.

2.0 INTRODUCTION

Nuaire’s NOXMASTER range has been specifically designed to improve 
the indoor air quality and provide a whole home ventilation solution. 
Combining the principles of positive input ventilation (PIV) and carbon 
filter technology the unit provides cleaner, fresher, filtered air into the 
a dwelling at a continuous rate, encouraging the movement of air from 
inside to outside. To achieve this, the unit is mounted in the loft space 
and draws air from either the loft space or ducted supply from the 
exterior of the house (dependant on the operating temperatures).

Unlike conventional PIV units, NOXMASTER units are fitted with 
dual inlets, which automatically select the air source based on the 
surrounding temperature:

If the loft temperature is below the set point (recommended 24°C) 
then the unit will take fresh air from the loft space.

If the loft temperature is above the set point (recommended 
24°C) then cooler fresh air will be taken from outside the dwelling 
through a ducted supply (if fitted). 

To improve the efficiency of the NOXMASTER unit, it is fitted with a 
carbon filter bypass. The bypass is controlled on a time basis and is 
programmed to operate during times of low pollution (e.g. night time 
when air pollution is lower).  

3.0 PACKAGING AND DELIVERY

Please ensure you have the ability to handle and store this unit, as 
it may be delivered in three individual boxes strapped to a pallet as  
shown below.

4.0 INSTALLATION

Successful operation of the fan depends entirely upon the unit being 
installed strictly in accordance with these instructions. Please read 
through this guide in its entirety before commencing installation and 
follow step by step to ensure a satisfactory completion. Whilst the 
installation of the NOXMASTER unit may be achieved by suitable 
persons, the provision of the electrical supply and the connection of the 
unit to the mains must be carried out by a qualified electrician.

Warning: Isolate from power supply before removing any covers. During 
installation/ maintenance ensure all covers are fitted before switching 
on the mains supply.

This appliance can be used by children aged from 8 years and above 
and persons with reduced physical, sensory or mental capabilities or 
lack of experience and knowledge if they have been given supervision 

POD A (Carbon Filter)

POD A (Carbon Filter)
Weight: 22Kg

POD B (Blower)

POD B (Blower)
Weight: 12Kg

AIRFLOW

1371

1381

Loft Intake

787

433

527

Ducted Intake
(Ø150mm Spigot supplied) 

119

Ø201

24

319

200

102

168

197

500

Figure 1. Unit Layout & Dimensions

Figure 2. Palleted DImensions

A

B

C

BOX 2

BOX 1

BO

X 3

Item

Dimensions (mm)

Weight 

(kg)

A

B

C

Euro Pallet

900

1200

800

BOX 1

981

585

362

22

BOX 2

685

585

362

12

BOX 3

535

230

340

6

Summary of Contents for NOXMASTER

Page 1: ... is important to ensure that the diffuser is NOT placed within 1 metre of a smoke alarm If the diffuser cannot be repositioned two sides of the diffuser must be closed off using the air dams supplied to encourage the air through the remaining open sides that faces at least 1 5 metres of unobstructed area away from the smoke alarm sensor If the unit is required to switch off in the event of smoke C...

Page 2: ...Nuaire s NOXMASTER range has been specifically designed to improve the indoor air quality and provide a whole home ventilation solution Combining the principles of positive input ventilation PIV and carbon filter technology the unit provides cleaner fresher filtered air into the a dwelling at a continuous rate encouraging the movement of air from inside to outside To achieve this the unit is mount...

Page 3: ...on of the ceiling vent Align the two pods with both spigots facing out leaving a space between the pods to make the electrical connection Figure 5 Release the free end of the fly lead from pod B and align the flats on the male connectors with the flats on the fixed connector in pod A Push the connectors together until the outer clips have fully engaged and the connection is secure Pull the pods to...

Page 4: ... screws provided and seal with silicone to eliminate air leakage Duct to the outside using ridged ducting Spigot Guard Punched out and removed 150mm inlet duct to outside Soffit grille Part No 775229 fixes over rectangular ducting which has been pulled through the rectangular hole 220mm X 80mm cut in soffit and folded flat up against the surface of the soffit Note that a minimum soffit width of 13...

Page 5: ...it Green yellow 5 2 2 NOXMASTER HEAT All Versions With Heater Heater Enable LED 7 3 Change Carbon Filter Alert The carbon filters are required to be changed every five years the display on the ceiling diffuser will show the letter C once this time has elapsed New filters can be purchased direct from Nuaire please refer to Section 8 0 below for further details To reset the change filter message on ...

Page 6: ...rol panel is illuminated the heater is active in autoheat mode and is controlled by the temperature setpoint When the orange LED is not lit the heater is off In order to enable the heater press the DOWN button for five seconds and release The orange LED will illuminate indicating that the heater is active and in auto heat mode To turn the heater off press the DOWN button for five seconds and relea...

Page 7: ... the equipment is modified without authorisation is incorrectly applied misused disassembled or not installed commissioned and maintained in accordance with the details contained in this manual and general good practice The product warranty applies to the UK mainland and in accordance with Clause 14 of our Conditions of Sale Customers purchasing from outside of the UK should contact Nuaire Interna...

Reviews: