Installation Manual

NOXMASTER - PIV with Carbon Filtration

5.0 ELECTRICAL CONNECTION

5.1 Electrical Details

Voltage:  

230V 1ph 50Hz

IMPORTANT

The fan unit is also supplied with a fused spur. The three core 

mains cable from the unit should be connected to a fixed 

wiring installation, via the spur, in accordance with current IEE 

wiring regulations.

5.2 Wiring Diagrams

5.2.1 NOXMASTER (All Versions Without Heater)

1A Fused Spur

(Supplied)

2 Pole Isolator

(By Others)

MAINS

230V

50Hz

N

L

Blue

Brown

Supply cord

from unit

Green/yellow

IMPORTANT

The electrical connection of the unit must be carried out by 

a qualified electrician. 

For good EMC engineering practice, the power supply output 

cable and any sensor cables should not be placed within 

50mm of other cables or each other.

4.3.3 Dual Inlets

The unit features a dual inlet which automatically selects the air source 
based on the surrounding temperature. To utilise this feature, the 
circular guard needs to be knocked out and the supplied spigot fitted 
(ensure the lose guard is removed from the unit). If ducted air supply is 
not being used, 

do not knock out guard.

Fix the required spigot to the unit with the screws provided and 
seal with silicone to eliminate air leakage.

Duct to the outside using ridged ducting. 

Spigot 

Guard - Punched 

out and removed

150mm inlet 
duct to outside

Soffit grille (Part No. 775229) fixes over rectangular 
ducting which has been pulled through the rectangular 
hole (220mm X 80mm) cut in soffit and folded flat up 
against the surface of the soffit.
Note that a minimum soffit width of 130mm is required.

Form end of 
rectangular ducting 
to fit connector 
and secure using 
dynotie connector.

150mm dia. 
insulated ducting 
connected to unit 
spigot using 
dynotie connector
(Part No. FLDI150).

220mm x 90mm flexible 
PVC Rectangular ducting 
(Part No. PVC933WH). 
Note: this duct should 
be kept as short as 
possible.

Circular duct connector
(Part No. RDC150).

150mm dia. insulated ducting

connected to unit spigot using

dynotie connector
(Part No. FLDI150). 

150mm dia. pipe

(Part No. PVC130-6WH).

Insulated duct formed over pipe 

and sealed with dynotie connector.

199 x 215 x 20mm 

white plastic wall grille 

(Part No. PVC604WH).

Figure 7. Fitting Dual Inlets

Figure 8. Soffit Installation

Figure 9. Wall Installation

Ceiling 

Joist

Metal 

Mounting 

Bracket

A.V.

Mount

A.V.

Mount

Washer

3” Woodscrew

50mm 

Min.

12mm 

Clearance 

Hole

Control Output

Time Clock (controls bypass damper)

Thermostat (controls intake damper)

Heater Output

Figure 4. Anti-Vibration Mount Installation

Figure 5. NOXMASTER-HEAT Installation

Figure 6. NOXMASTER-HEAT Installation

Summary of Contents for NOXMASTER

Page 1: ... is important to ensure that the diffuser is NOT placed within 1 metre of a smoke alarm If the diffuser cannot be repositioned two sides of the diffuser must be closed off using the air dams supplied to encourage the air through the remaining open sides that faces at least 1 5 metres of unobstructed area away from the smoke alarm sensor If the unit is required to switch off in the event of smoke C...

Page 2: ...Nuaire s NOXMASTER range has been specifically designed to improve the indoor air quality and provide a whole home ventilation solution Combining the principles of positive input ventilation PIV and carbon filter technology the unit provides cleaner fresher filtered air into the a dwelling at a continuous rate encouraging the movement of air from inside to outside To achieve this the unit is mount...

Page 3: ...on of the ceiling vent Align the two pods with both spigots facing out leaving a space between the pods to make the electrical connection Figure 5 Release the free end of the fly lead from pod B and align the flats on the male connectors with the flats on the fixed connector in pod A Push the connectors together until the outer clips have fully engaged and the connection is secure Pull the pods to...

Page 4: ... screws provided and seal with silicone to eliminate air leakage Duct to the outside using ridged ducting Spigot Guard Punched out and removed 150mm inlet duct to outside Soffit grille Part No 775229 fixes over rectangular ducting which has been pulled through the rectangular hole 220mm X 80mm cut in soffit and folded flat up against the surface of the soffit Note that a minimum soffit width of 13...

Page 5: ...it Green yellow 5 2 2 NOXMASTER HEAT All Versions With Heater Heater Enable LED 7 3 Change Carbon Filter Alert The carbon filters are required to be changed every five years the display on the ceiling diffuser will show the letter C once this time has elapsed New filters can be purchased direct from Nuaire please refer to Section 8 0 below for further details To reset the change filter message on ...

Page 6: ...rol panel is illuminated the heater is active in autoheat mode and is controlled by the temperature setpoint When the orange LED is not lit the heater is off In order to enable the heater press the DOWN button for five seconds and release The orange LED will illuminate indicating that the heater is active and in auto heat mode To turn the heater off press the DOWN button for five seconds and relea...

Page 7: ... the equipment is modified without authorisation is incorrectly applied misused disassembled or not installed commissioned and maintained in accordance with the details contained in this manual and general good practice The product warranty applies to the UK mainland and in accordance with Clause 14 of our Conditions of Sale Customers purchasing from outside of the UK should contact Nuaire Interna...

Reviews: