Installation and Maintenance

MRXBOXAB-ECO2-AESW Mechanical Ventilation Unit with Heat Recovery

Telephone 02920 858 400 

[email protected]

10.0 REPLACEMENT OF PARTS

Should any component need replacing, Nuaire keep extensive stocks 

for quick delivery. Ensure that the unit is electrically isolated, before 

carrying out any work.
Note: The supply cable must be replaced by an electrically competent 

person. 
When ordering spare parts, please quote the serial number of the unit 

and the ARC number of the purchase, if possible. (This information will 

be available on the fan label).

11.0 WARRANTY

The 5 year warranty starts from the day of delivery and includes parts 

and labour for the first year and parts only for the remaining 4 years. 
This warranty is void if the equipment is modified without 

authorisation, is incorrectly applied, misused, disassembled, or not 

installed, commissioned and maintained in accordance with the details 

contained in this manual and general good practice. 
The product warranty applies to the UK mainland and in accordance 

with Clause 14 of our Conditions of Sale. Customers purchasing from 

outside of the UK should contact Nuaire International Sales office for 

further details.

12.0 AFTER SALES

For technical assistance or further product information, including spare 

parts and replacement components, please contact the After Sales 

Department.

 

Outer enclosure cover

MVHR unit cover

Filter

Heat Exchanger

Filter cover

Figure 19. Removing the two filter covers on the front panel of the 

unit. The filters can be removed by pulling on the black tab on the 

visible end of the filters.

Summary of Contents for MRXBOXAB-ECO2-AESW

Page 1: ...n with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person for their safety Children should be supervised so that they do not play with the appliance 2 1 Transportation fixings To prevent damage during transportation the product is shipped with securing fixings the...

Page 2: ...ical example of a cupboard mounted unit Standard unit fixed to a stud partition with the MDF panel fixed behind the plasterboard 2 5 Condensate Drain The MVHR unit inside the enclosure is fitted with a straight coupling to allow 21 5mm overflow pipe not supplied to be attached using solvent cement the pipe should be passed through the flexible adhesive backed cover plate before the solvent cement ...

Page 3: ...outside of the outside air inlet duct and the air outlet duct from the unit these ducts should be insulated Ducting must be installed in such a way that resistance to airflow is minimised Bends should be kept to a minimum A minimum distance of 300mm between the appliance and any bends in ductwork is recommended Ideally 125mm diameter or 220 x 90mm rectangular ducting should be used Refer to dwelli...

Page 4: ...step 1 and step 2 Note that the maximum individual room extract rate should be at least those given in table 1 The minimum air supply rate should be at least the whole building ventilation rate found in step 1 For Scotland refer to BRE Digest 398 For further information refer to Domestic Ventilation Compliance Guide www planningportal gov uk buildingregulations approved documents partl compliance ...

Page 5: ... duct 4 0 DUCTING ARRANGEMENTS STANDARD CONFIGURATION Figure 12 Typical ducted arrangement for a wall mounted unit using circular ducting Figure 13 Typical ducted arrangement for a wall mounted unit using rectangular ducting Air supply to lounge in ceilings via AirValve Extract air from kitchen bathroom in ceilings via AirValve Exhaust air from kitchen bathroom to outside via louvre grille Minimum...

Page 6: ...ions in fig 14 are factory fitted The unit is pre wired with a 2 metre fly lead Fuse 2A MAINS 230V 50Hz light Room Light switch Double Pole N L 3 Pole isolator Kitchen switch Blue Brown Black Optional 3 speed switch Supply cord from unit Grey Green yellow Fuse 2A MAINS 230V 50Hz Room lights Light Double switches Pole N L 3 Pole isolator Kitchen switch Blue Green yellow Brown Black Supply cord from...

Page 7: ...or is measuring humidity from all the wet rooms at the same time and should not be relied on to solely boost the unit Additional switch should be used local to the wet rooms see wiring diagrams Nuaire recommend that filters are inspected every 6 months and replaced every 12 months A flashing LED section 7 0 will indicate that a filter change is required This indication repeats every 12 months and ...

Page 8: ...our for the first year and parts only for the remaining 4 years This warranty is void if the equipment is modified without authorisation is incorrectly applied misused disassembled or not installed commissioned and maintained in accordance with the details contained in this manual and general good practice The product warranty applies to the UK mainland and in accordance with Clause 14 of our Cond...

Reviews: