ES-OPUSDC
Installation Manual
3.1 Dimensions
View From Bottom
367 mm
Spigots 100 mm Ø
367 mm
184 mm
242 mm
Veiw From Side
8
Dimensions
4.0 ELECTRICAL INSTALLATION
Isolate from power supply before removing any covers. During
installation / maintenance ensure all covers are fitted before
switching on the mains supply.
For good EMC engineering practice, any sensor cables or switched
live cables should not be placed within 50mm of other cables or on
the same metal cable tray as other cables.
4.1 Electrical Information
Unit Size
Power Consumption
Full Load Current
ES-OPUSDC40
18 W
0.14 A
ES-OPUSDC60
44 W
0.32 A
ES-OPUSDC75
33 W
0.26 A
ES-OPUSDC110
75 W
0.61 A
9
Mains Cable, Clamp and PCB's
10
24 V Power Supply
SWL
N
L
230 V
50Hz
Mains
Supply
11
Ecosmart Control PCB
Min Max Run On Pwr Standby Fan 1 Fan 2
Fan 1
Fan 2
‘Net’ connections for
Ecosmart devices (4)
Switch to activate
continuous trickle
Volt Free Relay
Contacts
RUN FAULT
ON
OFF