3

06. 10. 20. Document Number  671139

Nuaire | 

Western Industrial Estate 

Caerphilly 

CF83 1NA 

|

 

nuaire.co.uk

ES-OPUSDC

Installation Manual

Wall Mounted Unit (Vertical)

Mounting Bracket 
Screws Into Wall

 

Bracket Clip

 

Opening Sealed Spigots

Ceiling Mounted Unit

Control 
Panel

Mounting

Bracket

Clip

Mounting Bracket

 Screws Into

 Ceiling

 
 
 
 
 
 

Wall Mounted Unit (Horizontal)

Mounting Bracket 
Screws Into Wall

Air extract from
WC for example. 
Grille available as 
an optional extra.

Air extract from 
bathroom for 
example. 
Grille available 
as an optional 
extra.

Air extracted to 
outside via 
combined supply / 
extract grille 
available as an 
optional extra .

Flexible ducting 
available as an 
optional extra.

Control panel

Typical Installation

Summary of Contents for ES-OPUSDC Series

Page 1: ...able guards If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard The replacement cord must be of the same t...

Page 2: ...fans run simultaneously All units incorporate speed control for both low and high speed along with adjustable run on facility and allow connection of Ecosmart sensors PIR humidistat etc The unit disc...

Page 3: ...ntrol Panel Mounting Bracket Clip Mounting Bracket Screws Into Ceiling 3 Wall Mounted Unit Horizontal Mounting Bracket Screws Into Wall Air extract from WC for example Grille available as an optional...

Page 4: ...d EMC engineering practice any sensor cables or switched live cables should not be placed within 50mm of other cables or on the same metal cable tray as other cables 4 1 Electrical Information Unit Si...

Page 5: ...tection These contacts are rated at 5A resistive 0 5A inductive 4 3 3 Run Connections These contacts are closed when the fan is running 4 3 4 Fault Connections No Fault Contacts are closed Fault Conta...

Page 6: ...er pieces plastic heat exchangers packaging material and other plastic components can be segregated into mixed plastic and widely recycled Cardboard packaging wood used filters and other paper compone...

Page 7: ...ould not be placed within 50mm or on the same metal cable tray as 230V switched live lighting or power cables and any cables not intended for use with this product In addition to the particular requir...

Page 8: ...8 06 10 20 Document Number 671139 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk ES OPUSDC Installation Manual NOTES...