ES-OPUSDC
Installation Manual
1.2 Important Information
This manual contains important information on the safe and
appropriate assembly, transport, commissioning, operation,
maintenance, disassembly and simple troubleshooting of the product.
While the product has been manufactured according to the accepted
rules of current technology, there is still a danger of personal injury or
damage to equipment if the following general safety instructions and
the warnings contained in these instructions are not complied with.
•
Read these instructions completely and thoroughly before
working with the product.
•
Keep these instructions in a location where they are accessible
to all users at all times.
•
Always include the operating instructions when you pass the
product on to third parties.
1.3 Personal Protective Equipment
The following minimum Personal Protective Equipment (PPE) is
recommended when interacting with Nuaire product:
•
Protective Steel Toed Shoes -
when handling heavy objects.
•
Full Finger Gloves (Marigold PU800 or equivalent) -
when
handling sheet metal components.
•
Semi Fingerless Gloves (Marigold PU3000 3DO or equivalent)
- when conducting light work on the unit requiring tactile
dexterity.
•
Safety Glasses
- when conducting any cleaning/cutting operation
or exchanging filters.
•
Reusable Half Mask Respirators
- when replacing filters which
have been in contact with normal room or environmental air.
Nuaire would always recommend a site specific risk assessment by a
competent person to determine if any additional PPE is required.
2.0 INTRODUCTION
The Nuaire range of low power duct mounted extract fans have been
specifically designed to ventilate areas such as toilets, bathrooms, small
offices, etc. The range consists of units for four duty ranges, 40 l/s, 60
l/s, 75 l/s and 110 l/s maximum extraction.
The 40 l/s and 60 l/s products are available as single fan or twinfan
variants, twinfan units are duty sharing. The 75 l/s and 110 l/s products
are dual fan only (both fans run simultaneously).
All units incorporate speed control for both low and high speed, along
with adjustable run-on facility and allow connection of Ecosmart
sensors (PIR, humidistat etc).
The unit discharges through 100mm diameter outlet spigot. Air enters
the unit through 3 off 100mm diameter spigots, the central spigot is
supplied open and the other two supplied closed but are easy to open
(Figure 7).
The motor is of the DC variant, fitted with self lubricating ball bearing
and locked rotor protection.
The unit is supplied with a quick release fan mounting bracket which
allows for installation in any configuration.
2.1 Code Description
1
2
-
3
ES-OPUSDC
40
-
2M
1. Range:
ES-OPUSDC
(Low Power Duct Mounted
Extract Fans wIth Ecosmart Control)
2. Unit Size:
40
=
40 l/s
60
=
65 l/s
75
=
75 l/s
110
=
110 l/s
3. Fan Arrangement:
M
= Single Fan (40 & 60 Duty Only) or
Dual Fan (75 & 110 Duty Only)
2M
= Twin Fan (40 & 60 Duty Only)
1
General View Of Unit
Extract to outside
Extract from
bathroom
for example.
Extract
from WC
for example.
3.0 MECHANICAL INSTALLATION
Installation must be completed by competent persons, in accordance
with good industry practice and should conform to all governing and
statutory bodies i.e. IEE, CIBSE, etc.
The unit is designed to be ceiling/wall mounted in any plane, with the
access panel for the wiring and controls on the underside. The fan must
be fitted indoors, away from any direct sources of heat, water spray or
moisture generation.
A clear working space is required around the installed unit to
allow the cover to be removed and provide sufficient access for
maintenance.
•
The integral mounting bracket supplied with the unit can be
offered up to position on the ceiling or wall (Figures 2 and 4).
•
The fixing points for the bracket should then be marked and the
bracket installed with two screws ensuring that the bracket is
secure on the ceiling or wall.
•
Offer the unit into position inside the bracket ensuring the access
cover is face down, and locate the bracket into the moulded
bracket holders on the case sides (Figure 3).
Various spigot positions can be utilised as required to suit the system
ductwork and extract grilles. The unit is supplied with one spigot open
and two ’closed’ as knockouts when delivered but they can be opened
using a hacksaw (Figure 7).