NTI VOPEX SERIES CAT5 USB KVM SPLITTER/EXTENDER
19
INTERCONNECTION CABLE WIRING METHOD
The connection cable between the VOPEX and each XTENDEX Remote Unit is terminated with RJ45 connectors and must
be wired according to the EIA/TIA 568B industry standard. Wiring is as per the table and drawing below.
RJ45 Connector Wiring
Pin
Wire Color
Pair
Function
1
White/Orange
2
T
2
Orange
2
R
3
White/Green
3
T
4
Blue 1
R
5
White/Blue
1
T
6
Green 3
R
7
White/Brown
4
T
8
Brown 4
R
Figure 9- View looking into RJ45 female
Note: CATx connection cable used between NTI VOPEX and the XTENDEX Series Remote or any XTENDEX Series
products should not be run underground, outdoors or between buildings.
WARNING: Outdoor or underground runs of CATx cable could be dangerous and will void the warranty.
TROUBLESHOOTING
Each and every piece of every product produced by Network Technologies Inc is 100% tested to exacting specifications.
We make every effort to insure trouble-free installation and operation of our products. If problems are experienced while
installing this product, please look over the troubleshooting chart below to see if perhaps we can answer any questions that
arise. If the answer is not found in the chart, a solution may be found in the knowledgebase on our website at
http://information.networktechinc.com/jive/kbindex.jspa
or please call us directly at (
800) 742-8324 (800-RGB-TECH)
or
(330) 562-7070
and we will be happy to assist in any way we can.
Problem
Cause
Solution
VOPEX power LED does
not illuminate
•
Power supply is not connected or
plugged-in.
•
Make sure the outlet is live and the AC adapter is
plugged-in. Make sure DC plug / AC line cord is fully
connected.
XTENDEX power LED
does not illuminate
•
VOPEX is not powered ON
•
CATx cable not connected
•
Make sure VOPEX is ON
•
Check that the CATx cable is snapped-in properly at
each end of the cable
No video on
monitor/display
•
One or more video cables is loose
or disconnected.
•
No power to the VOPEX or the
XTENDEX Remote Unit.
•
Video Cable was not attached
when video source was powered-
up.
•
CATx cable is not connected.
•
Cable is too long for the selected
resolution
•
Check all video cable connections
•
Make sure power LEDs are illuminated for local and
remote. If not, see solution for problem above.
•
With all the cables properly connected, cycle the power
to the video source.
•
Check cable connections. Make sure they are snapped-
in properly and reboot.
•
Check Distances and Resolutions chart on page 14.
T
1
+
R
2
-
T
3
+
R
4
-
T
5
+
R
6
-
T
7
+
R
8
-
Pair 2
Pair 1
Pair 4
Pair 3
!