Trinity Tx
Model Numbers: Tx
51
-
151
Version Date: 2013-06-20
INSTALLATION AND OPERATION INSTRUCTIONS FOR
TRINITY Tx BOILER
TABLE OF CONTENTS
1.0
INTRODUCTION ................................................................................................................ 3
2.0
SPECIFICATIONS .............................................................................................................. 6
3.0
BOILER LOCATION .......................................................................................................... 7
4.0
GENERAL VENTING ....................................................................................................... 10
5.0
VENT/AIR-INLET TERMINATION CLEARANCES ..................................................... 24
6.0
CONDENSATE DRAIN .................................................................................................... 27
7.0
INSTALLING GAS PIPING .............................................................................................. 29
8.0
LIGHTING THE BOILER ................................................................................................. 31
9.0
GAS VALVE AND BURNER SET-UP ............................................................................ 34
10.0
BOILER AND HEATING SYSTEM PIPING ................................................................... 37
11.0
DOMESTIC HOT WATER (DHW) PIPING – TX151C (COMBI) .................................. 48
12.0
FIELD WIRING ................................................................................................................. 52
13.0
CASCADE INSTRUCTIONS ............................................................................................ 55
14.0
WIRING SCHEMATICS ................................................................................................... 57
15.0
INSTALLATION CHECKLIST ........................................................................................ 59
16.0
ANNUAL MAINTENANCE AND INSPECTION ........................................................... 60
17.0
DISPLAY MENU GUIDE ................................................................................................. 62
18.0
TROUBLESHOOTING ..................................................................................................... 72
19.0
PARTS LIST ...................................................................................................................... 75
HAZARD SYMBOLS AND DEFINITIONS
Danger Sign: Indicates a hazardous situation which, if not avoided, will
result in serious injury or death.
Warning Sign: Indicates a hazardous situation which, if not avoided,
could result in serious injury or death.
Caution Sign plus Safety Alert Symbol: Indicates a hazardous situation
which, if not avoided, could result in minor or moderate injury.
Caution Sign without Safety Alert Symbol: Indicates a hazardous
situation which, if not avoided, could result in property damage.
Notice Sign: Indicates a hazardous situation which, if not avoided,
could result in property damage.
This Boiler must be installed by a licensed and trained Heating
Technician or the
Warranty is Void.
Failure to properly install this
unit may result in property damage, serious injury to occupants, or possibly death.
NTI # 84874
NEW PRODUCT LINE
High Efficiency
Condensing Gas Boiler
H