NTI VEEMUX VIDEO MATRIX SWITCH 

 

5

 

Connect the Sources and Monitors 

 
 

1.

 

Turn OFF power to all video sources (inputs) that will be connected to the VEEMUX before connecting or  

        disconnecting any cables. 
2.

 

Connect a VEXT-xx-MM cable from the video port of a video source to a 15HD female video connector 

        labeled VIDEO 1 on the VEEMUX.  (See Fig. 1) 
3.

 

Connect additional video sources to remaining 15HD female VIDEO x connectors as desired.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

                                                           Figure 3- Install Video Source Cables 

 
4.

 

Connect a monitor to the 15HD female connector labeled MONITOR 1 on the rear of the VEEMUX  (See Fig. 2). 

5.

 

Connect additional monitors to remaining 15HD female MONITOR x connectors as desired.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

                                             Figure 4- Connect a monitor to the VEEMUX

 

 

Summary of Contents for SM-4X2-15V-LC

Page 1: ...1 2012 SM nXm 15V LC Video Matrix Switch Installation and Operation Manual VEEMUX Series NETWORK TECHNOLOGIES INCORPORATED Tel 330 562 7070 Fax 330 562 1999 1275 Danner Dr Aurora OH 44202 www network...

Page 2: ...tted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written consent of Network Technologies Inc 1275 Danner Drive Aurora Ohio 44202 CHANGES The...

Page 3: ...2000 XP Vista and 7 13 SerTest RS232 Interface Test Program 14 Main Options 14 Matrix Operations 14 Ethernet Operations 14 Setup Options 15 Ethernet Control 16 Telnet Interface Port 2000 16 Telnet In...

Page 4: ...ll Video Source Cables 5 Figure 4 Connect a monitor to the VEEMUX 5 Figure 5 Connect user terminal for RS232 control 6 Figure 6 Connect the LAN to the VEEMUX 6 Figure 7 Connect Power to VEEMUX 7 Figur...

Page 5: ...ess of input RGsB monitor requires RGsB input Supported Web Browsers Most modern web browsers should be supported The following browsers have been tested Microsoft Internet Explorer 6 0 or higher Nets...

Page 6: ...e male used for INPUTS 3 thru 100 feet Multi coax high resolution VGA or SVGA video cable Connectors are 15HD male female used for OUTPUTS 3 thru 100 feet Multi coax high resolution VGA to BNC cable C...

Page 7: ...Illuminates to indicate communication between the hand held remote control and the VEEMUX 6 AC INPUT IEC Connector For attachment of the IEC power cord to power the VEEMUX 6a Fuse Fuseholder For repl...

Page 8: ...ne up with the holes in the mounting ear on the NTI switch 3 Secure the NTI switch to the rack using four 10 32X3 4 screws supplied Each screw should be of sufficient length to go completely through t...

Page 9: ...a video source to a 15HD female video connector labeled VIDEO 1 on the VEEMUX See Fig 1 3 Connect additional video sources to remaining 15HD female VIDEO x connectors as desired Figure 3 Install Video...

Page 10: ...re 5 Connect user terminal for RS232 control Connect to the Ethernet If the Telnet Interface page 16 or Web Interface page 21 will be used an Ethernet connection to the Local Area Network LAN must be...

Page 11: ...VIDEO MATRIX SWITCH 7 Power Up 1 Plug the VEEMUX into an AC power outlet 2 Turn ON power to the VEEMUX 3 Turn ON power to the video sources and monitors connected to the VEEMUX Figure 7 Connect Power...

Page 12: ...to source 3 etc Along with the routing of the inputs video sources to the outputs monitors the keypad and LCD allow the users to configure the RS 232 control interface The keypad buttons perform the f...

Page 13: ...re not used at this time and are therefore unnecessary 3 The third option in the main menu is Standby If you select Standby the VEEMUX switch will immediately go into a power saver mode and the LCD di...

Page 14: ...on to most CPUs see page 6 To daisy chain multiple units connect a Matrix Y 1 cable sold separately between the CPU and the first switch and between each switch as shown in Figure 8 Baud Rate The baud...

Page 15: ...D Female 9D Male 9D Male Wiring Schematic of Matrix Y 1 cable NTI SWITCH CPU RS232 First Unit NTI SWITCH RS232 NTI SWITCH RS232 Second Unit Last Unit RS232 Serial Port Matrix Y 1 Matrix Y 1 Matrix Y 1...

Page 16: ...xx xxx format number of digits is minimum 1 and maximum 3 for each field Leading zeroes are accepted EM SW ip CR Set the Subnet mask ip is in xxx xxx xxx xxx format number of digits is minimum 1 and m...

Page 17: ...es Message to the administrator will be delayed by any RS232 traffic being received by the switch from the administrator Autostatus must be disabled before using SerTest or the NTI Switch Control Prog...

Page 18: ...bank c Change All Units Baud Rate 9600 COM1 change RS 232 Baud rate of all switches the current baud rate and serial port are displayed in parentheses d Reset Unit send a reset command to the switch...

Page 19: ...ss current 1 select the unit address the current address is displayed in parentheses For any selection that requires user input the user is prompted When commands are sent to the matrix unit the comma...

Page 20: ...prompted to introduce the password twice Change password CS nn mm CR Connect One Output User Port To Input Video source CA nn CR Connect All Outputs To Input RO nn CR mm CR Read Connection For Output...

Page 21: ...rrent IP address at port 2005 Use the command set below to control and acquire information from the VEEMUX Note After establishing the connection the unit will answer with CR If the connection fails o...

Page 22: ...Byte 6 Byte 7 Byte 8 Byte 9 p 0x70 c 0x63 Space 0x20 Output 1st digit 0x30 0x32 Output 2nd digit 0x30 0x39 0x2C Input 1st digit 0x30 0x32 Input 2nd digit 0x30 0x39 CR 0x0D This command will read the c...

Page 23: ...x63 Space 0x20 Output 1st digit 0x30 0x32 Output 2nd digit 0x30 0x39 0x3A Input 1st digit 0x30 0x32 Input 2nd digit 0x30 0x39 CR 0x0D SS_00 Disable Auto Status Mode Command Byte 1 Byte 2 Byte 3 Byte 4...

Page 24: ...he telnet session The unit is then available for future connections It is recommended that the XX command is used as it will close the Telnet connection with the server immediately If the XX command i...

Page 25: ...dress into the address bar of the web browser Address To open a SSL encrypted connection type Address You will be prompted to accept a certificate Accept the NTI certificate A Login Page will appear F...

Page 26: ...an be saved and later recalled by any connection method Scanning Sequences page 28 for each output can also be enabled Note Changes made using the keypad page 8 or by another user through the web inte...

Page 27: ...e current connection selections the changes made by the other user will be saved as the configuration The webpage configuration that loads after a Save is the configuration that was actually saved To...

Page 28: ...t Names Assign port names to each cable connection from display devices for easy reference Scanning Sequence Assign dwell times for each input as it is assigned to each output s scanning sequence Chan...

Page 29: ...tion page Mode Choose between Static IP assignment and DHCP IP Address If using Static IP assignment enter a valid IP address to use Subnet Mask Enter a valid subnet mask value Default Gateway Enter a...

Page 30: ...on will stay logged in The range is 0 3200 minutes 0 disables it Any change to the Website Timeout configuration takes effect immediately Press the Save button to save any changes made Video Input Nam...

Page 31: ...ports displayed on the Switch page Figure 15 Video Output Names page To change an Output Name enter the name of the port for the desired output port number and press Save If you make changes and chan...

Page 32: ...unt of time that each will be viewed 0 255 seconds can be set to cycle sequentially for each connected output If an input is set to 0 seconds that input will not be viewed and will be skipped from the...

Page 33: ...ons and establish a connection and starting point for the scanning sequence Blocks shown in yellow in the third image indicate connections made 3 Click on the Sequence Enable box for each output from...

Page 34: ...to change the password used to access the VEEMUX This password is also used for the telnet interface Be sure to make note of the new password exactly as it is case sensitive The password must be betwe...

Page 35: ...rsion number and copy it to your computer 2 On the Update Firmware page in the Update File block browse to the firmware file 3 Press Upgrade Note If an update is attempted using the wrong firmware for...

Page 36: ...e VEEMUX is placed in Standby Mode When in Standby Mode the VEEMUX is still operating as configured but cannot be manipulated further until standby is disabled Standby Mode can be disabled either by p...

Page 37: ...Matrix Switch at NTI From there you can see what versions of firmware are available and determine if the version in your VEEMUX is current or in need of an upgrade page 31 Figure 21 Support Tab Reboo...

Page 38: ...d display the Device Discovery Tool page Note The Discovery Tool requires the Java Runtime Environment to operate A link to the web page from which it can be downloaded and installed is provided on th...

Page 39: ...es Routing of video and audio signals together or individually Ability to switch one input to all outputs Scroll through inputs for a single output by using the Input keys similar to changing channels...

Page 40: ...and volume settings Up to 10 configuration can be recalled 0 9 SYS Pressed to select the desired NTI system to be controlled Only used when controlling multiple systems Must be followed by a system n...

Page 41: ...s can be used to surf through input port connections However since there are multiple outputs users the question becomes which output connection is being changed As a result it is required that an out...

Page 42: ...using the asterisk button which selects all outputs With the input port selected pressing the button will immediately force the command to connect all output ports to the selected input Example Connec...

Page 43: ...address will illuminate the IR LED and respond to all IR Remote commands and will blink the IR LED on the front of the switch for visual indication All other switches will ignore any further commands...

Page 44: ...x 1200 60Hz Video Signal Video Bandwidth Sync RGB analog 75 ohms 0 7 Vp p 160MHz typ or greater H V separated TTL composite sync on green Ethernet Connector RJ45 female 10BaseT RS232 Connector RJ45 f...

Page 45: ...in no user serviceable parts In the event repair is needed all servicing must be performed by factory trained and authorized service personnel Only those items specifically identified in this manual i...

Page 46: ...two 2 years from the date of purchase Please contact Network Technologies Inc at 800 742 8324 800 RGB TECH or 330 562 7070 or visit our website at http www networktechinc com for information regardin...

Reviews: