NTI VEEMUX VIDEO MATRIX SWITCH
38
Jump To Input
With the output port selected, a user knowing the desired input port number can enter it using the Numeric keys (0-9).
Just as with using the “OUT” button, pressing the “IN” button after the number will force the command immediately. If the “IN”
button is pressed prior to the port number, the “ENTER” button must be pressed to avoid a two (2) second delay before the input
port is accepted.
Examples:
Quick method to change Output 1 from Input x (any) to Input 8:
<
1
> + <
OUT
> + <
8
> + <
IN
>
Quick method to change Output 12 from Input x (any) to Input 20:
<
1
> + <2> + <
OUT
> + <2> + <0> + <
IN
>
Jump To Output
Users can also change ports by specifying the input port number first. Similar to selecting the output port first, the “IN”
button can be pressed either before or after entering the port number. Once the input port has been selected, the output port can
be selected, following the same format as “Jump to Input…”
Expiration of a five (5) second timeout will force the switch to forget the entered input port number.
Example:
Quick method to change Input 1 from Output x (any) to Output 8:
<
1
> + <
IN
> + <
8
> + <
OUT
> (must enter the <x> + <
OUT
> command within 5 seconds of pressing <
IN>
)
Connect All
It may be desirable to broadcast the video (and audio) signals from one input to all of the outputs. In this situation, the
user can quickly make all of these connections by using the “ * ” (asterisk) button which selects all outputs. With the input port
selected, pressing the “ * “ button will immediately force the command to connect all output ports to the selected input.
Example :
Connect all users to Input 2:
<
2
> + <
IN
> + <
*
>
The “ * “ button can also be pressed prior to selecting the input port. In this case, the command will take effect once the
input port has been selected.
<
*
> + <
2
> + <
IN
>
If no command is received before the five (5) second timeout expires, the switch will forget the “ * “ key-press.
Save and Recall
The SM-8X8-LC-LCD video matrix switches provide the ability to save and recall up to 10 switch configurations. The switch
configurations define the current port connections and video blank status. The IRT-UNV IR Remote can be used to access these
configurations by using the “SAVE” and “RECALL” buttons.
To save a configuration, press the “SAVE” button followed by Numeric key(s) 0-99 corresponding to the memory slot the
configuration is to be saved in. After the numeric key(s) press the “Enter” button. If the “Enter” button is not pressed, after two
seconds the function will timeout and the number entered will be saved as that configuration.
Configurations can be recalled in much the same manner. To recall, press the “RECALL” button followed by the numeric key
(s) corresponding to the memory slot from which the configuration is to be recalled. After the numeric key(s) press the “Enter”
button. If the “Enter” button is not pressed, after two seconds the function will timeout and the number entered will be recalled to
the current configuration.