Lx – WH Series Installation and Operation Instructions
│
Trinity Lx
11
Figure 3-2(b) Wall Mounting Installations (Lx300WH-Lx400WH)
While leaving the upper bracket intact (A),
remove the wall mount bracket attached to the
Failure to follow instructions may
result in fire, serious injury, or death.
bottom-back of the boiler (B). Save the
mounting hardware for Step 4.
Secure the wall mount bracket, removed from
the bottom of the boiler in Step 1, to a solid
wall using field supplied lag screws (anchors
when mounting to a concrete wall) that are
adequate to support the weight of the boiler
(refer to Table 2-1 Specifications). Ensure the
wall mount bracket is mounted level and flush
to the wall with mounting holes on the bottom,
flange pointed upward and angled away from
the wall.
This unit requires two people to lift it
or damage and injury may result.
Mount the boiler to the wall by aligning the
upper bracket (A) with the wall mount bracket
(B). Slide the upper bracket down over the
wall mount bracket until it hooks.
Once the boiler is resting securely on the upper
bracket, secure the bottom bracket to the
underside of the boiler using the mounting
hardware removed in Step 1; then, anchor the
bottom bracket to the wall as shown.
Code requires all wall mounted instantaneous water heaters to be installed with suitable
wall protection extending the full length and width of the water heater. Check with local
authorities regarding acceptable protection materials.
B
A
Ensure that the
upper bracket
on the back of
the appliance
(A) slides down
over the wall
mount bracket
(B) and rests
securely on it.
A
B
Bottom Bracket is in
Lx Installation Kit Box
B