LinMot Installation Guide C1100
10 Physical Dimension
C1100 Series
single axis drive
C11xx-xx-XC-0S
C11xx-xx-XC-1S
Width
mm (in)
26.6 (1.05)
Height
mm (in)
146 (5.75)
166 (6.54)
Height with fixings
mm (in)
186 (7.3)
206 (8.1)
Depth
mm (in)
106 (4.2)
Weight
g (lb)
550
650
Mounting Screws
Mounting Distance
mm (in)
2 x M5
168 (6.61)
2 x M5
188 (7.4)
Case
IP
20
Storage Temperature
°C
-25…40
Transport Temperature
°C
-25…70
Operating Temperature
°C
0…40 at rated data
40...50 with power derating
Relative humidity
95% (non-condensing)
Pollution
IEC/EN
60664-1
Pollution degree 2
Shock resistance (16ms)
-1S option
3.5g
Vibration resistance (10-200Hz)
-1S option
1g
Max. Case Temperature
°C
90
Max. Power Dissipation
W
30
Mounting place
In the control cabinet
Mounting position
vertical
Distance between Drives
mm (in)
Without Power Derating:
20 (0.8) horizontal / 50 (2) vertical
With Power Derating:
5 (0.2) horizontal / 20 (0.8) vertical
NTI AG / LinMot
®
www.LinMot.com