Chapter 4 - Managing and Monitoring
One-Touch Annunciation Configuration Display
109
One-Touch Annunciation Configuration Display
The “One-Touch Annunciation” Configuration Display feature is an easily
accessible press-to-touch display of the SES Controller card switches 1 through 3
settings, fan speed control setting, Host I/O card and Disk I/O card bus speed
mode, presence of Disk I/O cards and Host I/O cards, and the presence of RAID
Controllers.
By pressing and holding the Alarm Reset button, the Drive Activity LEDs will all
be extinguished and the Drive Status LEDs will illuminate in unique combinations
to indicate the settings and conditions. Below is an illustration and a table that
describes the Drive Status LEDs and their meanings:
Status LED Call-Outs
Status LED Conditions
RESET ALARM
Rt Host I/O
Card Presence
Host I/O Bus
Speed Mode
SES Switch
AD0 Position
Lt Host I/O
Card Presence
Disk I/O Bus
Speed Mode
SES Switch
AD1 Position
Lower CNTRL
Presence
Upper Disk I/O
Card Presence
SES Switch
AD2 Position
Press and Hold
to display settings
Upper CNTRL
Presence
Lower Disk I/O
Card Presence
Auto Fan Speed
Control
One-Touch Annunciation Configuration Display
Slot 1
SES Switch AD0
Slot 4
SES Switch AD1
Slot 7
SES Switch AD2
Slot 10
Auto Fan Speed Control
Slot 2
Host I/O Cards Bus Speed Mode
Slot 5
Disk I/O Cards Bus Speed Mode
Slot 8
Upper Disk I/O Card Presence
Slot 11
Lower Disk I/O Card Presence
Slot 3
Right Host I/O Card Presence
Slot 6
Left Host I/O Card Presence
Slot 9
Lower Controller Presence
Slot 12
Upper Controller Presence
LED On = Up Position
LED Off = Down Position
LED On = Up Position
LED Off = Down Position
LED On = Up Position
LED Off = Down Position
LED On = Auto Control Enabled
LED Off = Disabled
LED On = 2Gb Mode
LED Off = 1Gb Mode
LED On = 2Gb Mode
LED Off = 1Gb Mode
LED On = Present
LED Off = Missing
LED On = Present
LED Off = Missing
LED On = Present
LED Off = Missing
Note: Both Host I/O cards must be set to the same mode setting, otherwise the LED will indicate 1Gb mode, this also applies to the Disk I/O cards.
LED On = Present
LED Off = Missing
LED On = Present
LED Off = Missing
LED On = Present
LED Off = Missing
4200F.book Page 109 Thursday, January 23, 2003 2:47 PM
Summary of Contents for NexStor 4200F Series
Page 2: ...4200F book Page 2 Thursday January 23 2003 2 47 PM...
Page 8: ...Table of Contents iv 4200F book Page iv Thursday January 23 2003 2 47 PM...
Page 12: ...About this Manual Features viii 4200F book Page viii Thursday January 23 2003 2 47 PM...
Page 32: ...Chapter 1 Getting Started Audible Alarm 20 4200F book Page 20 Thursday January 23 2003 2 47 PM...
Page 172: ...Index 160 4200F book Page 160 Thursday January 23 2003 2 47 PM...
Page 173: ...4200F book Page 161 Thursday January 23 2003 2 47 PM...