IMPORTANT SAFETY INSTRUCTIONS 

GROUNDING OF ELECTRICAL EQUIPMENT - BATTERY CHARGER 

WARNING:

  

Improper connection of the equipment–grounding 

conductor can result in a risk of electric shock.  Check with a qualified 
electrician or service person if you are in doubt as to whether the outlet 
is properly grounded.  Do not modify the plug provided with the 
charger.  If outlet is not suitable for safe use; have a properly grounded 
outlet installed by a qualified electrician. 
Always use a properly grounded 3-wire extension cord, which has 
male and female plugs.  If 25 foot extension cords are used, the 
electrical carrying capacity should be no less than 14-3 ST., 50-foot 
extension cords no less than 12-3 ST. 

GROUNDING INSTRUCTIONS 

This charger shall be grounded while in use to protect the operator from electric shock.  The charger is 
provided with a three-conductor cord and a three-contact grounding type attachment plug.  The plug must be 
plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes 
and ordinances.  The green conductor in the cord is the ground wire.  Never connect this wire to other than 
the grounding pin of the attachment plug. 

Check nameplate on the charger to be sure 

voltage

 and 

cycle

 stated is the same as the electrical outlet.  Do 

not attempt to plug a 120-volt charger into a 240-volt outlet or a 240-volt charger into a 120-volt outlet. If the 
cord provided with the charger has an attachment plug as shown in Figure A. below, it is intended for use on a 
nominal 120-volt circuit.  If a properly grounded receptacle as shown in Figure A is not available, an adapter 
may be installed as shown in Figure B if the outlet box that houses the receptacle is grounded.  Be sure to 
fasten the grounding tab (the green colored rigid ear, lug or the like extending from the adapter) with a metal 
faceplate screw. 
If the cord provided with the charger has an attachment plug as shown in Figure C, it is intended for use on a 
nominal 240-volt circuit (single phase only).  Changes to the attachment plug or use of adaptors to other plug 
types must be done in accordance with local regulations.  

 

 

  

NOTE:  In Canada, the use of a temporary adaptor may not be permitted by Canadian electrical code. 

ALL REPAIR SERVICE MUST BE PERFORMED BY AN NSS AUTHORIZED DISTRIBUTOR/ 
SERVICE STATION USING ONLY NSS ORIGINAL EQUIPMENT PARTS.

 

SAVE THESE INSTRUCTIONS

 

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Summary of Contents for CHAMP 3329 RB

Page 1: ...st lint hair etc NEVER pick up anything that is burning or smoking such as cigarettes matches or hot ashes NEVER spray this machine with water or any liquids NEVER allow the vacuum motor or battery ch...

Page 2: ...or maintenance free batteries ALWAYS check to ensure the battery water level covers the battery plates before charging ALWAYS check water level after charging and add distilled water if necessary to...

Page 3: ...than the grounding pin of the attachment plug Check nameplate on the charger to be sure voltage and cycle stated is the same as the electrical outlet Do not attempt to plug a 120 volt charger into a 2...

Page 4: ...moving in forward or reverse Traction Speed Switch 2 Positions Down is high speed Up is low speed Push Button Toggles between display screens Defaults to screen 1 when turned on Vacuum Switch 2 posit...

Page 5: ...tighten the mounting knobs Do not use pliers to tighten the knobs as this will defeat the breakaway design As the machine is used the squeegee blades wear out and need to be replaced due to damage Squ...

Page 6: ...st the liquid level Do not use well or tap water Before charging add only enough water to ensure the top of the plates are covered After charging add only enough water to bring the level to the bottom...

Page 7: ...Opportunity charge whenever possible Equalize after 30 days Flooded only Battery Charger The onboard battery charger supplied with this machine is capable of charging lead acid batteries from 185 to...

Page 8: ...ard setting for the onboard battery charger is Flooded AGM EXCEPTION If your machine was ordered from NSS equipped with Gel batteries then the charger was configured for Gel batteries at the factory C...

Page 9: ...refill the batteries with well or tap water flooded cell batteries e NEVER overfill the batteries flooded cell batteries f NEVER let the batteries sit discharged overnight or between shifts g ALWAYS...

Page 10: ...cuit exceeded current limit Check wiring or replace device 1321 Aux 1 over current 2 occurred Brush Lift Actuator exceeded current limit Check limit switch settings wiring or replace 1322 Aux 2 over c...

Page 11: ...brush inhibit Check Brush Motor for excessive amp draw when starting Repair or Replace as necessary 7605 Brush startup over current detection Check Brush Motor for excessive amp draw Check for locked...

Page 12: ...cal bottle empty Check fittings at bottle cap for leaks Replace squeeze tube if cracked Fill chemical bottle Possible Internal TRIO Faults Code Code Code Code Corrective Action 0003 1800 3104 3603 For...

Page 13: ...an dry clean terminals Battery terminals are dirty damaged Clean terminals and connectors replace damaged cables Electrolyte level is too low Add distilled water and charge Batteries are not fully cha...

Page 14: ...NOTES h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0...

Page 15: ...NOTES h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0...

Page 16: ...d Toledo Ohio 43607 PHONE 419 531 2121 FAX 419 531 3761 NSS Asia Limited Shanghai Building 188 Lane 1421 East Zhuan Xin Road Min Hang District Shanghai China 201108 PHONE 021 61371251 FAX 021 61371252...