TROUBLE SHOOTING – SIDEKICK CHEMICAL DISPENSOR
PROBLEM CAUSE SOLUTION
Sidekick pump not operating
Turned off, water valve is off, brushes
turned off
Ensure pump, solution valve, and
brushes are on.
Improper
wiring
Inspect/repair by qualified technician
Sensor
plugged
Remove sensor and blow air (5psi
max) thru in the opposite direction as
the arrow on the part to clear the
obstruction.
Sidekick operating, but not pumping
chemical
Vacuum leak at fittings on bottle cap,
Squeeze tube cracked, chemical
bottle empty
Check fittings at bottle cap for leaks.
Replace squeeze tube if cracked. Fill
chemical bottle.
Possible Internal TRIO+ Faults
Code
Code
Code
Code
Corrective Action
0003
1800
3104
3603 For All Internal TRIO + Diagnostic Codes:
0100
1802
3105
3608 1 - Turn Off Key switch and disconnect batteries.
0204
1B20
3200
3609 2 - Wait 1 minute.
0705
1B21
3201
360a 3 - Reconnect Batteries and turn On Key switch.
0706
2102
3210
360b 4 - If Diagnostic Code is not cleared, then replace TRIO+.
0A01 2103 3211 360c
0B02 2D01 3212 360d
0B0B 3100 3213 360e
1704 3101 3214 7501
1705
3102
3601
1706
3103
3602