NVR-9000 & NVR-9000S USER MANUAL
NVR-9000 & NVR-9000S UM.E 20200220-11
38
Unit
:
Actual unit of equipment. Such as degree (
°
).
Equipment:
User connected device.
Calibration point1, Calibration point1 value, Calibration poin2, Calibration point2 value:
The purpose of analog calibration is to convert the analog quantity of the actual input to the
physical quantity to be displayed.
For example:
A001 analog channel input
±
10V (4~20ma) analog, playback displays the rudder blade angle,
-10V (4mA) corresponding to the left 35
°
, 10V (20mA) corresponding to the right
35°
. Unit is "
°
" .
Input -10 in calibration point1, input -35 in calibration point1 value .
Input 10 in calibration point2, input 35 in calibration point2 value .
In an ideal situation, the playback interface will be in accordance with the acquisition of the value and
the four points of the linear relationship between the received analog conversion to physical quantity
for playback.
Note
:
Two sets of data must be filled to be able to correct the real analog conversion, otherwise the
actual values displayed by default to 0.
As shown below, two group A001 respectively (-10, -35), (10,35).
In VDR playback software shown in Figure: