RICERCA GUASTI

TROUBLE SHOOTING

manca tensione a vuoto

lack of no-load voltage

?

Avvolgimento in cto o difetto di isolamento o 
connessioni difettose. Controllare le resistenze degli 
avvolgimenti (vedi tabella) e l`isolamento: sostituire lo 
statore

?

perdita della magnetizzazione: sostituire "rorore con 
magneti

?

Short circuit in winding or fault insulation or loose 
connections. Check the windings resistances (as table) 
and the insulation: replace stator

?

loss of residual magnetism: replace rotor with magnets

Tensione a vuoto bassa

Too low no load voltage

?

Velocitá del motore troppo bassa: regolarla

?

Perdita parziale del magnetismo a seguito di elevato 
riscaldamento

?

Too low engine speed: adjust it

?

Loss of residual magnetism due to high overheating

Tensione a vuoto alta

Too high alternator no load voltage

?

Velocitá del motore troppo alta: regolarla

?

Too high engine speed: adjust it

Tensione corretta a vuoto ma bassa a carico.

Correct no-load voltage but low load voltage

?

Possibile sovraccarico: controllare la corrente di 
carico, rispristinare il carico corretto

?

Il motore rallenta: contattare il costruttore del motore; 
possibile scelta errata del motore

?

velocità a carico troppo bassa: regolarla

?

Possible overload: check value of load current, restore 
the correct load

?

The engine speed falls off: contact the engine 
specialist; too low engine power

?

Too low rotation speed: adjust it

Surriscaldamento della macchina

over heating

?

Circuito di ventilazione parzialmente ostruito: pulire

?

Possibile sovraccarico: controllare la corrente di 
carico, rispristinare il carico corretto

?

Ventilation inlet-outlet partially blocked: clean it

?

Possible overload: check value of load current, restore 
the correct load

Tensione instabile

Unstable voltage

?

Contatti incerti: controllare le connessioni

?

Irregolaritá di rotazione: verificare l'uniformitá di 
rotazione (contattare il costruttore del motore).

?

Loose contacts: check connections

?

Uneven rotation: check for uniform rotation speed 
(contact the engine specialist)

Macchina Rumorosa

Noisy Generator

?

Accoppiamento difettoso: verificare e riparare

?

Raschiamento statore/rotore: verificarne 
l'allineamento; contattare nostro Ufficio Tecnico

?

Poor coupling: check and repair

?

Scraping between stator and rotor: check aligniment; 
contact our technical dept

Summary of Contents for PMG-DC

Page 1: ...anenti Permanent Magnet Generator MANUALE D USO E MANUTENZIONE USE AND MAINTENANCE MANUAL NSM S r l Via Lazio 5 b 36015 Schio Vicenza Italy tel 39 0445 595888 fax 39 0445 595800 www nsmsrl it info nsmsrl it 201504 PMG GS PMG DC ...

Page 2: ......

Page 3: ...il gruppo funzioni senza vibrazioni o rumori anomali e che le aperture di aspirazione esplusione aria se presenti non siano ostruite Dati tecnici non impegnativi NSM si riserva il diritto di apportare modifiche senza l obbligo di darne preventiva comunicazione INSTRUCTIONS WARNING The operating instructions include only the directions to be followed by the qualified personnel they must always be s...

Page 4: ...ono anche da fissaggio laterale del coperchio utilizzare qui 2 rondelle Ø5 15 ASSEMBLING INSTRUCTIONS PMG R B3 B9 form CAUTION before assembling verify that the conical coupling parts both engine and PMG are clean and not damaged If stated tightening torques are specified between square brackets Mount the coupling shield to the engine by using adequate screws and washers not provided 25Nm Approach...

Page 5: ...tween square brackets In order the make easier the operation of centering screw on the flywheel of the engine 2 threaded pins M8x30 Approach the pmg unit to the engine centering the holes on the joint with the threaded pins Align holes on pmg and engine flanges and fix by means of appropriate screws and washers not provided 40Nm Handling through the air outlets screw and fix the screws not provide...

Page 6: ...avvitare alternativamente le 3 viti in modo da estrarre gradualmente il gruppo flangia statore dal rotore con magneti Una volta completata l estrazione afferrare il gruppo flangia statore e rimuoverlo RIASSEMBLAGGIO PMG Avvitare completamente le 3 viti M10x60 nelle apposite sedi sulla flangia pmg Approssimare con cautela il gruppo flangia statore centrando nel contempo lo statore al rotore con mag...

Page 7: ...al board SAE Nel caso di optional aggiuntivi far riferimento alle relative istruzioni specifiche fornite In case of additional optionals please refer to the related instructions provided filter PMG ferrite black brown white blue red grey yellow green nero marrone bianco blu rosso grigio giallo verde noire marron blanc bleu rouge gris jaune vert schwartz braun weiss blau rot grau gelb negro marron ...

Page 8: ...iferimento alle relative istruzioni specifiche fornite In case of additional optionals please refer to the related instructions provided PMG black brown white blue red grey yellow green nero marrone bianco blu rosso grigio giallo verde noire marron blanc bleu rouge gris jaune vert schwartz braun weiss blau rot grau gelb negro marron blanco azul rojo gris amarillo verde grüne S1 Stator AUX nominal ...

Page 9: ...e Raddrizzatore Singolo Single Rectifier Bridge Ponte Raddrizzatore multiplo Multiple Rectifier Bridges i collegamenti al carico vanno effettuati dall utilizzatore finale nel caso di ponti raddrizzatori multipli si consiglia di non connetterli direttamente al carico utilizzando invece morsettiere adeguate dalle quali poi realizzare le connessioni connections to the load must be made by the final u...

Page 10: ...tinare il carico corretto Il motore rallenta contattare il costruttore del motore possibile scelta errata del motore velocità a carico troppo bassa regolarla Possible overload check value of load current restore the correct load The engine speed falls off contact the engine specialist too low engine power Too low rotation speed adjust it Surriscaldamento della macchina over heating Circuito di ven...

Page 11: ... months from NSM invoice date During that period NSM engages in repairing or replacing at its option at its charge at its premises all those parts which failed without any other type of liability direct or indirect 2 The decision about warranty operating time approval is NSM s exclusive right and is subjected to a previous examination of the failed parts which will have to be forwarded free of cha...