background image

16

17

<Handpiece>

Trouble

Cause / Check

Remedy

The handpiece does 

not run with the 

chuck tightened.
Heat is generated 

during rotation.
Vibration or noise 

occurs during rotation.

Runout of the bur is 

heavy.

The bur comes out

Entry of foreign matter in the ball 

bearings or seizure.

Entry of foreign matter in the ball 

bearings, causing wear of the bearings.
Same as the above.
A bent bur is used.
Dust may be stuck in the chuck or 

spindle.
The chuck is worn.
The ball bearings are worn.

The chuck is loose.

Send it to your dealer. Ask for 

repair.

Same as the above.

Same as the above.
Replace the bur.
Clean the inside of the chuck and 

spindle.
Replace the chuck.
Send it to your dealer.
Tighten the chuck securely. (See 

12. Handling of Motor and 

Handpiece.)

Trouble

Cause / Check

Remedy

The motor and handpiece do not run, or Reset Lamp lights.

Trouble

Cause / Check

Remedy

The rotation speed 

does not rise.

The air turbine does 

not rotate.

English

Error code E9 

appears.

Error code EF 

appears.

If you have two or more units, 

replace the motor cord and 

check the operation.

Maintenance Mode (3) “Pd”: 

Check whether Foot Pedal 

operates normally by Foot Pedal 

Chuck.
The maximum rotation speed for 

operation by Foot Pedal should 

be set with the Speed Control 

Knob.
The connector of the turbine 

adapter is disconnected.
The tube connected to the air line 

kit is bent or pinched.
The turbine adapter is faulty 

and/or the Ultimate XL-K/D is 

faulty.

If it operates normally after replacing 

the motor cord, the motor and/or the 

motor cord may be shorted. Ask for 

repair of the motor and/or the motor 

cord. If the same error code still 

appears after replacing the motor 

cord, ask for repair of the unit.

If it does not operate normally, change 

the Foot Pedal for new or ask for 

repair.

Check the connector of the turbine 

adapter, and re-insert it correctly.

Check the tube to the air line, and flow 

the air.
Ask for repair of the turbine adapter 

and/or the Ultimate XL-K/D unit.

Ask for repair of the turbine adapter 

and/or the Ultimate XL-K/D unit.

The motor and handpiece do not run, 

or Reset Lamp lights.

Error code E3 

appears.

Error code E4 

appears.

Error code E5 

appears.

Error code E6 

appears.

Error code E8 

appears.

The motor cord is disconnected.

Maintenance mode (3) “HL”: 

Confirm whether you work by a 

motor signal check normally.

The chuck is open.
Check turning a tip with a finger 

lightly and turning around it 

lightly.

After stopping to cool it down 

place for about 10 minutes, 

check the operation again.

Vacuum-coupled Mode is on, 

while the dust collector is not 

used.
Turn on the power again, and 

repeat starting and stopping 

several times.
The chuck is open.
Check turning a tip with a finger 

lightly and turning around it 

lightly.

Maintenance mode (3) “HL”: 

Confirm whether you work by a 

motor signal check normally.

Turn on the power again.

If you have two or more units, 

replace the motor cord and 

check the operation.

Connect the motor cord correctly.
If any problem is found during a check, 

the motor cord may be severed or the 

sensor in the motor may be faulty. Ask 

for repair.
Lock the chuck.

If the rotation is abnormal, ask for 

repair of the motor and handpiece.

If it operates normally, there is no 

problem. Check the operating 

environment, storage location, etc., for 

high temperature. If the same error 

code appears frequently, ask for repair 

of the unit.
Make the Vacuum-coupled Mode to 

be off. See Vacuum-coupled Mode 

section in the manual.
If it operates normally, there is no 

problem. If the same error code 

appears, ask for repair of the unit.
Lock the chuck.

If the rotation is abnormal, ask for 

repair of the motor and handpiece.

If any problem is found during a check, 

the motor cord may be severed or the 

sensor in the motor may be faulty. Ask 

for repair.
Error indication is a temporary thing by 

the overload if I work normally. There is 

not it abnormally.
If it operates normally after replacing 

the motor cord, the motor and/or the 

motor cord may be shorted. Ask for 

repair of the motor and/or the motor 

cord. If the same error code still 

appears after replacing the motor 

cord, ask for repair of the unit.

Summary of Contents for NE231

Page 1: ...OPERATION MANUAL Micromotor for Laboratory Work English ...

Page 2: ...ine Option 6 Protective Circuit 7 Memory Function 8 Error Code 9 Replacement of Fuse 10 Maintenance Mode 11 Vacuum coupled Mode 12 Handling of Motor and Handpiece 13 Handpiece Stand 14 Specification 15 Troubleshooting 16 Disposing Product 1 5 6 7 8 8 8 9 9 10 10 11 12 14 14 15 18 Contents WARNING When using electric tools basic safety precautions should always be followed to reduce the risk of fir...

Page 3: ...zed cord will cause a drop in line voltage resulting in loss of power and overheating Table below shows the correct size to use depending on cord length and nameplate ampere rating If in doubt use the next heavier gauge The smaller the gauge number the heavier the cord 9 Install equipment so that the power supply cord can be pulled out without hindrance in event of emergency 1 For your own safety ...

Page 4: ...oto may cause damage 25 Do not turn the bur lock Chuck Control Ring while the handpiece is rotating 26 Do not rotate the motor when the bur lock Chuck Control Ring is at OPEN position or a bur is not mounted in the chuck It may cause the motor handpiece disconnection or sudden heat generation 27 Activation of Circuit Breaker means too much load is applied to the motor beyond the capacity the motor...

Page 5: ...t to the switch will light up If the desired speed is set with the Knee Controller or the Pedal and a uniform speed can be maintained for one second the motor will continue running at the desired speed if the Knee Controller or the Pedal is released To cancel it depress the Knee Controller or the Pedal again or press Auto Cruise Switch again 6 7 1 Mounting of the Unit 1 ULTIMATE XL K Bore a hole w...

Page 6: ... given to the rotation direction 7 Memory Function When the motor is stopped due to some trouble such as a failure overload wire breakage or misuse Speed Display displays the error code for checking the status of the unit and understanding the cause of the trouble easily 8 Error Code Fig 7 CAUTION Use of 40 000min 1 rpm or more is allowable only when the bur manufacturer or dealer specifies that t...

Page 7: ... To release Maintenance Mode turn Power Switch off and switch on again 1 oP Switch check operation check Press the switches on the panel and the right and or left lamps will light to check to see if the switches operate normally 2 dP Display check Press Forward Reverse Selector Switch and the lamps will light one by one to check to see if they operate normally To cancel this check press Forward Re...

Page 8: ...tc accumulate in the chuck and the bur is caught insecurely causing runout OPEN LOCK Loosen Loosen Loosen Fig 11 Loosen Loosen Loosen 3 Insertion of Chuck Thinly apply oil before insertion Open the Chuck Control Ring insert the dummy bur or the bur in use into the chuck and turn the chuck clockwise by hand until it stops Then lock the Chuck Control Ring and the chuck could hold the bur securely Fi...

Page 9: ... cord and check the operation The motor cord is disconnected If you have two or more units replace the motor and the motor cord and check the operation Insert the power plug correctly Replace it with a specified fuse If the reason the fuse has blown is unknown ask for an inspection Ask for repair Power on the Control Unit without pressing the Foot Pedal When it does not work definitely take off th...

Page 10: ...unit Ask for repair of the turbine adapter and or the Ultimate XL K D unit The motor and handpiece do not run or Reset Lamp lights Error code E3 appears Error code E4 appears Error code E5 appears Error code E6 appears Error code E8 appears The motor cord is disconnected Maintenance mode 3 HL Confirm whether you work by a motor signal check normally The chuck is open Check turning a tip with a fin...

Page 11: ...18 Please consult with dealer from whom you purchased it about waste disposal 16 Disposing Product ...

Reviews: