Maximum number of dimmers.

This parameter must be set to reflect a number greater than or equal to the maximum number of dimmer channels
installed in the system.  The factory default is 32 dimmer channels.  If this number is correct then this step may
be ignored.

The maximum number of dimmers may be set as follows:

1.

Make sure that the 400CP is in the program select mode as discussed.

2.

Press the zone 1 increase button and the BUSY led will quit flashing.

3.

Press button representing desired number of dimmers as shown in the diagram.

4.

If more than 256 dimmers are required then press a second button so that the sum of the values of the two
buttons pressed will equal the desired number of dimmers.

5.

The unit will exit this programming mode and the BUSY LED will start flashing again on release of the
second press, or after a few seconds if only one press was required.

 

400CP REMOTE CONTROL PANEL

PROGRAMMING

Software Revision 3.00, Version C

Maximum number of dimmers.

NSI CORPORATION

5

Summary of Contents for LUMA-NET 400CP

Page 1: ...fade times Remote lockout capability is also included Installation is a snap with the simple 4 wire digital connection required IMPORTANT Programming differs from older 400CP panels prior to release 3...

Page 2: ...or components MOUNTING The 400CP will mount in any standard double gang electrical box with the 4 screws provided See below paragraph on system turn on before final mounting of panels SYSTEM TURN ON...

Page 3: ...re bad ID While programming the following actions are normal Quickly flashing Programming mode no mode selected Off Programming mode mode selected LOCKOUT Any 400CP may be disabled from operation with...

Page 4: ...down all ZONE 1 4 LOWER buttons while connecting terminal block Full Memory Clear Normally the 400CP will not require memory clearing Once the memory is cleared all parameters including fade rate must...

Page 5: ...e zone 1 increase button and the BUSY led will quit flashing 3 Press button representing desired number of dimmers as shown in the diagram 4 If more than 256 dimmers are required then press a second b...

Page 6: ...red zone to be programmed At this point all currently assigned dimmers will come on The current dimmer selector will be set to one 4 Use the buttons marked as UP and DOWN in diagram to increment or de...

Page 7: ...pressed If the factory default setting of 5 seconds is desired for each zone then this step may be ignored To program zone fade time 1 Make sure that the 400CP is in the program select mode as discus...

Page 8: ...m mode as discussed 2 Press the zone 4 increase button and the BUSY LED will stop flashing 3 Look up the necessary sequence of 1 s and 0 for the ID number on the chart at the end of this section 4 Usi...

Page 9: ...s without dipswitch 1 Make sure that the 400CP is in the program mode as discussed 2 Press the zone 1 2 3 4 increase buttons at the same time and the BUSY LED will stop flashing 3 Look up the necessar...

Page 10: ...1100 62 01111100 63 11111100 64 00000010 65 10000010 66 01000010 67 11000010 68 00100010 69 10100010 70 01100010 71 11100010 72 00010010 73 10010010 74 01010010 75 11010010 76 00110010 77 10110010 78...

Page 11: ...hannels assigned to the selected zone and decrease lighting levels at the programmed fade rate Release button when correct lighting levels are attained To restore control from a console Simply perform...

Page 12: ...r or replace at its option defective materials provided you have identified yourself as the original owner of the product to NSI or any authorized NSI dealer Transportation charges to and from an auth...

Reviews: