NSF Kasco CertiSafe PM-100 Assembly & Installation Manual Download Page 9

PM-100 CERTISAFE™ PIPE MOUNT

MANUAL

852113 / 2021.1.1

9

MOUNT ASSEMBLY

With multiple options in both the upper and lower mount assemblies, the PM-100 allows for versatile adjustment of the unit’s position 

and angle within the tank. For ease of use and movement, Kasco recommends running the cable from the unit through the hollow 

center of the pipe. 

Upper Mount Base Installation

1. 

Install the upper mount base (A) 

as desired within the tank (hard

-

ware not included).

Fig. 8: Hole location and dimensions for the upper mount base (A). 

E

F

Fig. 9: Vertical mounting option

Fig. 10: horizontal mounting option

2.  Insert the 

1/2”-13 x 1/4” shoulder screw (E) as specified below for either vertical (Fig. 9) or horizontal (Fig. 10) mounting. 

3. 

Fasten with a serrated flange nut (F).

Back to Contents

Summary of Contents for Kasco CertiSafe PM-100

Page 1: ...CertiSafe Pipe Mount Assembly Installation Manual 800 Deere Rd Prescott WI 54021 715 262 4488 sales kascomarine com www kascomarine com Document number 852113...

Page 2: ...Supplies 4 Parts Included 5 Tank Penetration for Cable Support and Cord Grip 7 Mount Assembly 9 Cable Support 14 CertiSafe Tank Mixer Maintenance Recommendations 15 CertiSafe Tank Mixer Warranty 16 No...

Page 3: ...installation of a CertiSafe Tank Mixer These may include but are not limited to OSHA CCOHS and other regulations related to Working over or near water Fall protection systems Falling object protectio...

Page 4: ...any protective coatings Please consult your CertiSafe sales representative for mixer mount placement retrieval and inspection requirements Note some parts will arrive pre assembled from Kasco however...

Page 5: ...x 5 hex head screw 2 566250 K 3 8 16 x 1 hex head screw 2 840140 L 3 8 split lock washer 2 566230 M 3 8 16 nylon locknut 4 462214 Tank Penetration N 5 16 eye bolt 1 566226 O 5 16 nylon lock nut 1 5662...

Page 6: ...r mount base A Upper mount pipe bracket B Upper mount lock handle C Serrated flange screw D Shoulder screw E Serrated flange nuts F Steel tank roof Cable support U Lower mount strut plate I Lower moun...

Page 7: ...from the tank hatch This is for the cord grip S 2 Deburr both sides of the hole 3 Drill a 3 8 clearance hole about 4 from the hole drilled in step 1 This is for the eye bolt N 4 Deburr both sides of t...

Page 8: ...th washers P Q through the 3 8 hole 10 From the tank exterior fit a second flat washer P onto the eye bolt 11 Fasten the 5 16 nylon locknut O to the eye bolt 12 Tighten the locknut until snug being ca...

Page 9: ...the cable from the unit through the hollow center of the pipe Upper Mount Base Installation 1 Install the upper mount base A as desired within the tank hard ware not included Fig 8 Hole location and...

Page 10: ...the can strap with a 3 8 16 x 1 hex head screw K lock washers L and nylon lock nut M Be sure that there is a lock washer on either side of the flanges Fig 11 3 inches G Maintain alignment Fig 12 K M...

Page 11: ...Fig 16 Fig 14 6 The mounting position of the unit is adjustable Align the center hole in the strut block assembly with the left center or right hole in the can strap assembly to position the CertiSaf...

Page 12: ...rdware and ensure components are secure to the pipe without over tightening Fig 19 Fig 18 Fig 20 Fig 21 1 inch H 5 Slide the upper mount pipe bracket B over the pipe and cable Ensure the notched end o...

Page 13: ...he pipe bracket until it rests on the shoulder screw 11 Install the 1 2 13 x 1 3 4 serrated flange screw D in the top hole on the bracket and secure with a serrated flange nut F Note Steps 8 through 1...

Page 14: ...le support U Fig 27 Fig 28 4 Continue to feed power cable through the cord grip S and out of the tank until all excess cord length has been taken up leaving only enough so that there is no strain on t...

Page 15: ...n alert you to problems with the mixer It is important to test the GFCI upon installation after each re installation and regularly thereafter to ensure consistent operation If you experience repeat in...

Page 16: ...he motor assembly unless specifically requested by a Kasco representative Please attach a repair form with the shipment The repair form must include a name physical address for return delivery of the...

Page 17: ...stated dollar amount Example Please repair if total is under 150 00 before shipping charges Kasco will recycle any unit we receive for estimate but which the customer declines to repair unless the cu...

Page 18: ...ructed A fee of 60 per hour will be assessed for cleaning excessively dirty units Refer to the CertiSafe Tank Mixer Operation Maintenance Manual for easy to follow troubleshooting tips to rule out sit...

Reviews: