NSF Kasco CertiSafe PM-100 Assembly & Installation Manual Download Page 15

PM-100 CERTISAFE™ PIPE MOUNT

MANUAL

852113 / 2021.1.1

15

CERTISAFE™ TANK MIXER MAINTENANCE RECOMMENDATIONS

CERTISAFE™ TANK MIXER MAINTENANCE RECOMMENDATIONS

Electrical Troubleshooting

•  If a unit fails to operate, you can use a series of simple checks to determine the general cause. 

•  Once you’ve located the fault, please contact your distributor for information on how to proceed with repair.

Is the GFCI Tripped?

1.  If yes, reset the GFCI and check operation.

2.  If the GFCI continues to trip, disconnect the unit in the panel and reset the GFCI.

•  If the GFCI doesn’t trip, the fault lies in the unit or its cord.

•  If the GFCI continues to trip, the fault lies in the control panel power source.

Is the cord damaged?

1.  With the power off, perform a visual inspection of the power cord.

•  If there is visible damage, contact your distributor for repair options.

What happens with an alternate 

power source?

1.  If the power cord and unit appear to be in good condition, safely plug it into an 

alternate GFCI-protected power source. 

•  If the unit starts and continues to run, fault lies in the control panel or power 

source.

•  If the alternate GFCI continues to trip,  fault lies in the unit or cord.

GFCI 

• 

GFCI (Ground Fault Circuit Interrupter) is a safety feature 

that can alert you to problems with the mixer. It is important 

to test the GFCI upon installation, after each re-installation, 

and regularly thereafter to ensure consistent operation. If 

you experience repeat interruptions, disconnect and remove 

the equipment. Inspect the power cord and unit (mixer) for 

damage. If no damage is apparent, please contact your 

Kasco distributor or representative for further instruction.

Observation

•  Monitor the operating mixer for any reduction or variation in 

performance. 

•  Inspect the mixer annually and clean as needed to allow for 

heat dissipation and to verify that the propeller is clean and 

free of  nicks.

•  Inspect the power cable annually for damage or abrasion 

and replace as necessary.

•  Regularly clean all external rotating parts and examine them 

for wear.

• 

If you note a deficiency in performance, remove the equip

-

ment from service and inspect for any damage or failure. If 

you observe any canister leakage during annual inspection, 

send the mixer to Kasco’s factory for service and repair.

Cleaning 

•  The stainless-steel motor housing needs to be kept clean in 

order to allow heat to effectively dissipate.

Seal and Oil Replacement

•  Replacing the seal and changing the oil every 3-5 years will 

add reliability and longevity to the mixer.

•  Seal replacement and all other repair services should be 

performed by Kasco Marine. 

IMPORTANT: Disconnect electrical power prior to any maintenance or servicing!

Back to Contents

Summary of Contents for Kasco CertiSafe PM-100

Page 1: ...CertiSafe Pipe Mount Assembly Installation Manual 800 Deere Rd Prescott WI 54021 715 262 4488 sales kascomarine com www kascomarine com Document number 852113...

Page 2: ...Supplies 4 Parts Included 5 Tank Penetration for Cable Support and Cord Grip 7 Mount Assembly 9 Cable Support 14 CertiSafe Tank Mixer Maintenance Recommendations 15 CertiSafe Tank Mixer Warranty 16 No...

Page 3: ...installation of a CertiSafe Tank Mixer These may include but are not limited to OSHA CCOHS and other regulations related to Working over or near water Fall protection systems Falling object protectio...

Page 4: ...any protective coatings Please consult your CertiSafe sales representative for mixer mount placement retrieval and inspection requirements Note some parts will arrive pre assembled from Kasco however...

Page 5: ...x 5 hex head screw 2 566250 K 3 8 16 x 1 hex head screw 2 840140 L 3 8 split lock washer 2 566230 M 3 8 16 nylon locknut 4 462214 Tank Penetration N 5 16 eye bolt 1 566226 O 5 16 nylon lock nut 1 5662...

Page 6: ...r mount base A Upper mount pipe bracket B Upper mount lock handle C Serrated flange screw D Shoulder screw E Serrated flange nuts F Steel tank roof Cable support U Lower mount strut plate I Lower moun...

Page 7: ...from the tank hatch This is for the cord grip S 2 Deburr both sides of the hole 3 Drill a 3 8 clearance hole about 4 from the hole drilled in step 1 This is for the eye bolt N 4 Deburr both sides of t...

Page 8: ...th washers P Q through the 3 8 hole 10 From the tank exterior fit a second flat washer P onto the eye bolt 11 Fasten the 5 16 nylon locknut O to the eye bolt 12 Tighten the locknut until snug being ca...

Page 9: ...the cable from the unit through the hollow center of the pipe Upper Mount Base Installation 1 Install the upper mount base A as desired within the tank hard ware not included Fig 8 Hole location and...

Page 10: ...the can strap with a 3 8 16 x 1 hex head screw K lock washers L and nylon lock nut M Be sure that there is a lock washer on either side of the flanges Fig 11 3 inches G Maintain alignment Fig 12 K M...

Page 11: ...Fig 16 Fig 14 6 The mounting position of the unit is adjustable Align the center hole in the strut block assembly with the left center or right hole in the can strap assembly to position the CertiSaf...

Page 12: ...rdware and ensure components are secure to the pipe without over tightening Fig 19 Fig 18 Fig 20 Fig 21 1 inch H 5 Slide the upper mount pipe bracket B over the pipe and cable Ensure the notched end o...

Page 13: ...he pipe bracket until it rests on the shoulder screw 11 Install the 1 2 13 x 1 3 4 serrated flange screw D in the top hole on the bracket and secure with a serrated flange nut F Note Steps 8 through 1...

Page 14: ...le support U Fig 27 Fig 28 4 Continue to feed power cable through the cord grip S and out of the tank until all excess cord length has been taken up leaving only enough so that there is no strain on t...

Page 15: ...n alert you to problems with the mixer It is important to test the GFCI upon installation after each re installation and regularly thereafter to ensure consistent operation If you experience repeat in...

Page 16: ...he motor assembly unless specifically requested by a Kasco representative Please attach a repair form with the shipment The repair form must include a name physical address for return delivery of the...

Page 17: ...stated dollar amount Example Please repair if total is under 150 00 before shipping charges Kasco will recycle any unit we receive for estimate but which the customer declines to repair unless the cu...

Page 18: ...ructed A fee of 60 per hour will be assessed for cleaning excessively dirty units Refer to the CertiSafe Tank Mixer Operation Maintenance Manual for easy to follow troubleshooting tips to rule out sit...

Reviews: