4.6 Replace Battery
Remove low-capacity battery: Press the empty battery and push it outward
with a little strength, operate as shown by Figure 7 (left one and middle one).
Install additional spare battery: Put spare battery into the socket besides
control panel and push it until it is firmly in place, operate as shown by Figure
7 (right one).
NOTE:
1. Make sure the LED is in OFF state before battery replacement and installation.
2. Make sure the AC adapter is disconnected with power supply before you
need install or remove the battery from recharging socket of EL-P/S/T series.
CAUTION: Please use original accessories.
4.7 Recharge Battery
Recharging the battery is necessary when its capacity is not enough. Battery
remaining capacity will reduce with working time, in low battery station, the
internal buzzer (for EL-Q series) or LED lamp’s flashing (for EL-P/T/S series)
will remind user recharging. Check
Table 5 for further instructions.
13
Figure 7 Replace Battery