8-5
8.4 Parameter List
I/O
Address
Name
Data
format
Initial
value
Data
range
Description
Parameter
No.
4100
(4164)
Protected switch
USINT
0
0
~
16
Designate the number pf protected channels where
setting changes cannot be made, even if in the
PRGM mode.
65
4101
(4165)
Channel output status
during 1-axis offline
condition (when not in RUN
mode)
USINT
0
0
In test mode: All output OFF
In other modes: All output OFF
66
1
In test mode: Output HOLD
In other modes: Output HOLD
2
In test mode: All output OFF
→
Outrput
In other modes: All output OFF
3
In test mode: Output HOLD
→
Output
In other modes: Output HOLD
4102
(4166)
Channel output status
during 1-axis offline
condition (when in RUN
mode)
USINT
0
0
All output OFF
67
1
HOLD
8.4.1 Number of protected channels (I/O address: 4100 [4164])
A ‘protected channel’ is a ‘channel’ where settings cannot be changed or deleted in PRGM mode
(manual mode) of the external setting unit (VS-T62 or VS-T62B). The relationship between the
‘number of protected channels’ setting value and the corresponding channel Nos. as follows:
0: None
1: Channel No. 0
2: Channel Nos. 0 – 1
:
16: Channel Nos. 0 – 15
(1) To cancel the protected channel setting, enter ‘0’ as the setting value for ‘Protected switch’
(parameter No. 65).
(2) This setting is effective only when the VS-T62 or VS-T62B is connected.
8.4.2 Offline output status setting – TEST, INIT, PRM and PRGM mode (I/O address: 4101 [4165])
Designates the limit switch output status when offline in the TEST, INIT, PRM, and PRGM mode.
0: All outputs OFF (TEST mode), All outputs OFF (INIT, PRM and PRGM mode)
1: Hold (TEST mode), Hold (INIT, PRM and PRGM mode)
2: All outputs OFF
→
output (TEST mode), All outputs OFF (INIT, PRM and PRGM mode)
3: Hold
→
output (TEST mode), Hold (INIT, PRM and PRGM mode)
A ‘Hold’ setting means that the most recent limit switch output status of each channel is maintained.
However, if the power is turned OFF when an ‘output Hold’ status exists, that limit switch output will be
turned OFF when the power is turned back ON.
A ‘
→
output’ means that limit switch output is executed by pressing [SET] key of the VS-T62 or
VS-T62B.
8.4.3 Offline output status setting – RUN mode (I/O address: 4102 [4166])
Designates the limit switch output status when offline in the RUN mode.
0: All outputs OFF
1: Hold
A ‘Hold’ setting means that the most recent limit switch output status of each channel is maintained.
However, if the power is turned OFF when an ‘output Hold’ status exists, that limit switch output will be
turned OFF when the power is turned back ON.
Summary of Contents for Varlimit VS-212DN
Page 1: ...U S E R S MAN U AL V S 2 1 2 DN NSP Z2004 7...
Page 2: ......
Page 47: ...5 1 5 Operations 5 1 Operating Sequence Flowchart An operation flowchart is shown below...
Page 52: ...6 2 6 1 Pre Operation Setting Sequence...
Page 64: ...6 14...
Page 66: ...6 16...
Page 90: ...7 22...
Page 102: ...8 11...
Page 104: ...8 13...
Page 105: ...8 14...
Page 106: ...8 15...
Page 109: ...8 18...
Page 110: ...8 19...
Page 111: ...8 20...
Page 113: ...8 22...
Page 114: ...8 23...
Page 115: ...8 24...
Page 121: ...10 1 10 DIMENSIONS 10 1 VS 212DN Units mm...
Page 124: ...10 4 10 4 ABSOCODER sensor Units mm...
Page 125: ...10 5 Units mm...
Page 126: ...10 6 10 5 Extension Cable 1 4P S 0102 L 4P RBT 0102 L Units mm...
Page 128: ......
Page 129: ......
Page 130: ......
Page 131: ......
Page 132: ......
Page 133: ......
Page 134: ......