Specifications
Standard Output:
250ml/hr
Capacity of water tank: 3.4L
Noise level: 35dBA
Rated Voltage:
230V~
Rated Frequency:
50Hz
Power:
35W
Storage Instructions
When the product is left unused over a period of time, ensure that both the
water tank and water channel are clean. After cleaning, leave it to dry and
return to the original box for storage.
Product Disposal Information
Do not mix products bearing the crossed out bin symbol with your general
household waste. For the correct collection and treatment of these
products take them to the collection points designated by your local
authority. Alternatively contact the retailer who sold you the product.
Service & Warranty
NScessity Products guarantees this product free from defects in materials
and workmanship for a period of one (1) year. Should this unit be
operated under conditions other than those recommended, at voltages
other than the voltage indicated on the unit, incorrect battery operation, or
any attempts made to service or modify the unit, this will render this
WARRANTY VOID. The product you buy may sometimes differ slightly
from illustration. This warranty is in addition to, and does not affect, your
statutory rights.
Should you have a problem with this product, please contact our help desk,
Tel: 0870 765 2574.
This product has been manufactured to comply with EEC Directives
73/23/EEC and 89/336/EEC
NScessity Products
GU8 6BD
NSUH-342/IM/01
Trouble Shooting Guide
If in the event your unit is not working, please check the following
Fault Symptom
Analysis
How to fix
Power Cable unconnected
Connect Power Cable
Power light off, no
airflow and no mist
Main Switch off
Switch on the Main
Switch
No water in the Water Tank
Fill water into Water Tank
Power light on, with
airflow but no mist
Water Level Switch is not at
the proper position
Reinstall the Water Level
Switch Cover
Brand new product
Leave Tank Cover open in
cool place for 12 hours
Peculiar smell
from/in the Water
Tank
Dirty water or water stayed
in the Water Tank too long
Clean Water Tank and
replace/fill with fresh
clean water
Power light on, no
airflow and no mist
Water level too high in the
Water Basin
Take out some of the
water from the Basin
Too much scale on
Transducer
Clean Transducer
Small Output
Dirty water or water stayed
in the Water Tank too long
Clean Water Tank and
replace/fill with fresh
clean water
Too less water in Water tank
Fill more water into the
Water Tank
Abnormal noises
Unit is standing on uneven
or leaning surface
Place the unit on flat,
stable surfaces
Mist flowing down
unit not out of
Nozzle
There are gaps between
Nozzle and Water Tank
Ensure lid is fitted
correctly.
Water in Tank
doesn’t flow down
The movement of the
Rubber Seal in the Tank
Cover is blocked
Clean the tank cover to
remove the sticky dirt and
free the Rubber Seal.