1.  Safety Regulations 

 
VERY IMPORTANT: Instruments and components supplied by npi electronic are NOT 
intended for clinical use or medical purposes (e.g. for diagnosis or treatment of humans), 
or for any other life-supporting system. npi electronic disclaims any warranties for such 
purpose.  Equipment  supplied  by  npi  electronic  must  be  operated  only  by  selected, 
trained  and  adequately  instructed  personnel.  For  details  please  consult  the GENERAL 
TERMS OF DELIVERY AND CONDITIONS OF BUSINESS of npi electronic, D-71732 
Tamm, Germany.
 
 
1)

 

GENERAL:  This  system  is  designed  for  use  in  scientific  laboratories  and  must  be 
operated only by trained staff. General safety regulations for operating electrical devices 
should be followed. 

 
2)

 

AC MAINS CONNECTION: While working with the npi systems, always adhere to the 
appropriate  safety  measures  for  handling  electronic  devices.  Before  using  any  device 
please read manuals and instructions carefully. 
The  device  is  to  be  operated  only  at  115/230  Volt  60/50  Hz  AC.  Please  check  for 
appropriate line voltage before connecting any system to mains. 
Always  use  a  three-wire  line  cord  and  a  mains  power-plug  with  a  protection  contact 
connected to ground (protective earth).  
Before opening the cabinet, unplug the instrument. 
Unplug  the  instrument  when  replacing  the  fuse  or  changing  line  voltage.  Replace  fuse 
only with an appropriate specified type. 

 
3)

 

STATIC  ELECTRICITY:  Electronic  equipment  is  sensitive  to  static  discharges.  Some 
devices such as sensor inputs are equipped with very sensitive FET amplifiers, which can 
be damaged by electrostatic charge and must therefore be handled with care. Electrostatic 
discharge  can  be  avoided  by  touching  a  grounded  metal  surface  when  changing  or 
adjusting  sensors.  Always  turn  power  off  when  adding  or  removing  modules, 
connecting  or  disconnecting  sensors,  headstages  or  other  components  from  the 
instrument or 19” cabinet.
 

 
4)

 

TEMPERATURE  DRIFT  /  WARM-UP  TIME:  All  analog  electronic  systems  are 
sensitive to temperature changes. Therefore, all electronic instruments containing analog 
circuits should be used only in a warmed-up condition (i.e. after internal temperature has 
reached  steady-state  values).  In  most  cases  a  warm-up  period  of  20-30  minutes  is 
sufficient. 

 
5)

 

HANDLING:  Please  protect  the  device  from  moisture,  heat,  radiation  and  corrosive 
chemicals. 

 

Summary of Contents for DPA-2FS

Page 1: ...FOR THE DPA 2FS DIFFERENTIAL AMPLIFIER FILTER MODULE FOR EPMS SYSTEMS VERSION 2 0 npi 2015 npi electronic GmbH Bauhofring 16 D 71732 Tamm Germany Phone 49 0 7141 9730230 Fax 49 0 7141 9730240 support...

Page 2: ...S E 07 Housing 4 2 5 EPMS 03 5 2 6 PWR 03D 5 2 7 System Grounding 6 EPMS 07 EPMS 03 6 EPMS E 07 6 2 8 Technical Data 6 EPMS 07 EPMS E 07 and EPMS H 07 6 EPMS 07 and EPMS H 07 6 EPMS E 07 6 EPMS 03 6 3...

Page 3: ...efore connecting any system to mains Always use a three wire line cord and a mains power plug with a protection contact connected to ground protective earth Before opening the cabinet unplug the instr...

Page 4: ...ems are shipped with the EPMS 07 housing EPMS 07 cabinet with built in power supply Mains cord Fuse 2 A 1 A slow inserted Front covers Figure 1 Left front view of empty EPMS 07 housing In order to avo...

Page 5: ...wer supply unit the power switch and the fuse are located at the rear of the housing see Figure 2 right 2 6 PWR 03D The external power supply PWR 03D is capable of driving up to 3 EPMS E housings Each...

Page 6: ...to the SYSTEM GROUND SIGNAL GROUND on the rear panel of the instrument see Figure 4 The chassis can be linked to PROTECTIVE EARTH by connecting it to the PWR 03D with the supplied 6 pole cable and by...

Page 7: ...nce is 10 M Thus the module can be used for direct recording of bioelectric signals e g from peripheral nerves Using the differential input configuration common mode signals and noise are removed allo...

Page 8: ...DPA 2FS User Manual version 2 0 page 8 3 4 Description of the Front Panel and Operation Figure 5 DPA 2FS front panel view...

Page 9: ...OFFSET potentiometer 10 turn potentiometer for compensating for a DC OFFSET Note The overall OFFSET compensation is the product of the reading of both controls Important Position 5 of the OFFSET poten...

Page 10: ...LEDs indicating that the DPA 2FS exceeds its linear range 10 V 7 OUT connector BNC connector providing the conditioned signal 8 9 IN IN connector BNC connectors for connecting the input signal The in...

Page 11: ...i 15 1641 1645 Huemmeke M Eysel U T Mittmann T 2004 Lesion induced enhancement of LTP in rat visual cortex is mediated by NMDA receptors containing the NR2B subunit J Physiol 559 875 882 Schulz D Hust...

Page 12: ...1 1 V or 10 V set by toggle switch HIGHPASS Filter single pole attenuation 6 dB octave corner frequencies Hz 0 3 5 100 300 400 500 600 800 1k 3k 10k LOWPASS Filter single pole attenuation 6 dB octave...

Reviews: