30
EN
12.
Technical parameters
XIO 2.0
Voltage
100 – 240 V / 50 – 60 Hz
Energy consumption
2,5 A
Rated power
250 W
Standby mode (power)
0,3 W
Ambient conditions required for operation
Temperature: +5 °C do +40 °C
Humidity: 10 % do 85 %
Ambient conditions required for transport and storage
Temperature: -25°C to +70°C
Humidity: 5% to 90%
Temperature b55°C and
+70°C acceptable for a maximum of 24 hours
Maximum evenly distributed load
100 kg
Maximum time of continuous operation
2 minutes on / 18 minutes off
Adjustment range
640 – 1300 mm (max. Hub: 660 mm)
Noise emissions:
45 < dB(A)
Lifting speed:
38 mm / s
Anti-collision
External gyro sensor