Type of error
Cause
Solution
The workstation does not move
Disconnected power cord
Connect the power cord, check its
connection to the control module.
No connection or inaccurate con-
nection of electrical components
Check the component connections
to the control module.
No connection to the control panel
Connect the control panel to the
control module.
Maximum load exceeded
Reduce the load.
Continuous adjustment time
exceeded
Reactivation will take place after
3 minutes.
Note:
The maximum time of uninterrupted
operation of the lifting mechanism
is 2 minutes, followed by a break in
desk adjustment of at least
18 minutes.
DRIVE damage
Contact the Customer Service.
Control module damage
Drive damage
The workstation performs only
a slow downward movement
The control module forces initialisa-
tion or reset
Perform system initialisation / first
start-up following the user manual.
The workstation moves slowly
Maximum load exceeded
Reduce the load on the desk top.
The workstation makes a short
movement in one direction
No connection or inaccurate con-
nection of electrical components
Check the component connections
to the control module.
Damaged drive
Contact the Customer Service.
9.
Malfunctions cause and solution
26
EN