1  SAFETY AND ASSEMBLY 

REGULATIONS

Further information on Novy products, accessories and 
services may be found on the internet: www.novy.co.uk

These are the installation instructions for the appliance 
as shown on the front. The directions for use are in a 
separate booklet supplied with the appliance. 

These installation instructions make use of a number of 
symbols. The meanings of the symbols are shown below.

Symbol

Meaning

Action

Indication

Explanation of an  
indication on the hood.

Warning

This symbol indicates 
an important tip or a 
dangerous situation

Observe this instruction in order to prevent injury and 
damage to property.
 

 

Warnings before installation

 

− This appliance complies with the applicable safety 

instructions. However, inexpert installation may cause 
personal injury or damage to the appliance.

 

− The appliance is intended exclusively for household 

use (preparation of food) and excludes all other do-
mestic, commercial or industrial use. Do not use the 
appliance outside.

 

− Check the condition of the appliance and the installation 

fittings as soon as you remove them from the packag-
ing. Remove the appliance from the packaging with 
care. Do not use sharp knives to open the packaging. 

 

− Do not install the appliance if it is damaged, and in 

that case inform Novy.

 

− Check on the basis of the drawing 1 that all the ma-

terials for installation have been supplied. The grease 
filters are in the appliance.

 

− Novy is not liable for damage resulting from incorrect 

assembly, incorrect connection, incorrect use or in-
correct operation.

 

− The installation and electrical connection of the appli-

ance should be left to a recognised expert.

 

− Safety is guaranteed only with expert installation in 

accordance with the installation manual. The installing 
technician is responsible for proper operation at the 
installation location. 

 

− For easier installation of the appliance, it is advisable 

to carry it out with at least 2 people.

 

− Read the directions for use and the installation instruc-

tions before installing and using this appliance. You 
will find important information here for the assembly 
and use of the appliance.

 

− Metal parts may have sharp edges, and you may in-

jure yourself on them. For that reason, wear protective 
gloves during installation.

 

Installation instructions for the appliance

 

− Ensure that the structure on or in which the appliance 

is to be installed can bear its weight.

 

− Faulty or damaged parts may only be replaced by 

original Novy parts.

 

− The greater the distance between the appliance and 

the hob, the less easily the cooking vapours can be 
taken up by the appliance. For this reason, pay heed 
to the stated (recommended) installation height.

 

− In order to ensure that the cooking vapours are taken 

up in an optimal way, the appliance, or the structure into 
which the appliance is being installed, should extend 
over the hob. When using your own structure, ensure 
that the appliance is installed centred above the hob.

 

− For optimal operation, the hob should not be larger 

than the appliance or the structure into which the ap-
pliance is installed.

 

Exhaust or recirculation

This cooker hood, which is connected to an external 
motor from Novy, can only be used with an extraction 
duct to the outside and is not suitable for recirculation.

 

Install the exhaust duct

For optimum performance of the cooker hood it is im-
portant to pay attention to the following points:

 

− The motor outlet has a diameter of 150 mm. It is recom-

mended to connect an exhaust duct with a diameter 
of 150 mm to this.

 

− You will achieve the best operation and lowest possible 

noise level for the appliance by connecting the extrac-
tion duct by as short a route as possible, with as few 
bends as possible and using the prescribed diameter.

 

− Use smooth, non-flammable pipes with an internal 

diameter that is equal to the external diameter of the 
connection nozzle of the hood. 

 

− Use flat duct with rounded corners and with air de-

flectors. Available at Novy.

 

− Do not reduce the exhaust diameter. This will lower 

the capacity and raise the noise level.

 

− Avoid right-angle bends. Use rounded bends for ef-

fective airflow.

 

− Use of a flexible extraction hose should be kept to a 

minimum, and it should only be used for making small 
bridging sections, for example as the link between the 
outlet nozzle and the extraction duct. Maximally extend 
flexible ducts and cut them to size.

 

− Ensure that the extraction duct is not crushed and that 

there are no kinks in the duct.

 

− Use a hose clamp or aluminum tape for airtight con-

nections.

 

− With a horizontal extraction duct, install it at a slight 

incline to ensure that condensation does not run back 
to the appliance.

 

− Condensation may arise as a result of temperature 

differences if the extraction duct passes through cool 
rooms. Ensure that the extraction duct is insulated.

Summary of Contents for Pureline Cubic 6835

Page 1: ...NL Montage instructie 2 FR Instructions d installation 5 DE Montageanleitung 8 EN Installation Instructions 11 6835 110078 MA1 Novy Pure line Cubic 6835 6836 6845 6846...

Page 2: ...wijzing en de montage instructie v r de installatie en ingebruikname van dit toestel Hierin vind u belangrijke informatie voor de montage en gebruik van het toestel Metalen onderdelen kunnen scherpe k...

Page 3: ...k in de ruimte niet groter zijn dan 4 Pa 0 04 mBar De onderdruk kan worden voorkomen door niet afsluitbare openingen bijvoorbeeld in ramen of deuren in combinatie met een ventilatiekast in de muur vol...

Page 4: ...94x227x80 mm 906 402 Horizontale bocht afm 94x227x290 mm 906 403 Verticale bocht afm 94x175x227 mm 906 404 Bocht 15 afm 94x227x138 mm 906 418 Hoekadapter afm 94x227x205 mm 906 405 Overgangsstuk naar 1...

Page 5: ...ter des ar tes vives et peuvent occasionner des blessures D s lors portez des gants qui vous en pr servent lors de l as semblage Prescriptions de montage de l appareil Veillez ce que la structure sur...

Page 6: ...tre vit e avec des ouvertures non obturables par exemple dans des fen tres ou des portes en combinaison avec un bo tier de ventilation dans le mur qui permettent de faire entrer suffisamment d air dan...

Page 7: ...m 906 401 Raccord dim 94x227x80 mm 906 402 Coude horizontal dim 94x227x290 mm 906 403 Coude vertical dim 94x175x227 mm 906 404 Coude 15 dim 94x227x138 mm 906 418 Raccord d angle dim 94x227x205 mm 906...

Page 8: ...mit mindestens zwei Personen durchzuf hren Lesen Sie die Gebrauchsanweisung und Montageanlei tung sorgf ltig durch bevor Sie dieses Ger t installieren und in Betrieb nehmen Darin sind wichtige Informa...

Page 9: ...n geleitet werden Das Ger t saugt Luft aus der K che und angrenzenden R umen an Wenn die Luftzufuhr nicht ausreicht entsteht ein Unterdruck Die giftigen Gase werden aus dem Schorn stein oder Abzugssch...

Page 10: ...6 Zubeh r flacher Abluftkanal Flexibler Abluftkanal L nge 750 mm 906 408 Abluftkanal L nge 1000 mm 89x222x1000 mm 906 401 Verbindungsst ck 94x227x80 mm 906 402 Horizontaler Bogen 94x227x290 mm 906 403...

Page 11: ...iance Ensure that the structure on or in which the appliance is to be installed can bear its weight Faulty or damaged parts may only be replaced by original Novy parts The greater the distance between...

Page 12: ...e for a proposal on suitable measures in the area of air supply When using the appliance with an internal or external motor unit with air extraction to the outside there must be adequate air supply in...

Page 13: ...el duct1000 mm dimensions 89x222x1000 mm 906 401 Connection piece dimensions 94x227x80 mm 906 402 Horizontal curve dimensions 94x227x290 mm 906 403 Vertical curve dimensions 94x175x227 mm 906 404 Curv...

Page 14: ...ne Montage h he bei einem Gas oder Induktionskochfeld betr gt mindestens 650 mm und h chstens 1600 mm FR Le plafonnier peut tre encastr dans des plaques ayant une paisseur de 18 35 mm Ne montez pas le...

Page 15: ...cht in der Mitte an der Bodenplatte nach oben in den Ausschnitt bis Sie vier Mal ein Klicken der Halteklammern h ren Die Deckeneinheit bleibt jetzt h ngen und h ngt um circa 1 cm nach unten heraus FR...

Page 16: ...16 5 4...

Page 17: ...einheit auszubauen m ssen die vier Halteklammern von den Schrauben vollst ndig gel st werden Sobald sie gel st sind bewegt sich die Deckeneinheit nach unten Denken Sie daran dass die gel sten Haltekla...

Page 18: ...18 Afmetingen Dimensions Abmessungen Dimensions 6835 6836 1 2 3 4 18 35 240 420 30 81 111 480 508 840 868 150 240 3 1 2...

Page 19: ...19 Afmetingen Dimensions Abmessungen Dimensions 6845 6846 1 2 3 4 240 18 35 570 30 111 81 240 480 508 1140 1168 2 3 1 150...

Page 20: ...eit und ohne Vorbehalt die Konstruktion und die Preise ihrer Produkte zu ndern NOVY nv reserves the right at any time and without reservation to change the structure and the prices of its products NOV...

Reviews: