GENERAL INFORMATION

Note: these mounting instructions are applicable for multiple types of extractor hood. It is possible that they contain in-
formation that does not apply for your extractor hood.

General
These are mounting instructions for the Novy extractor hood shown on the front. The user manual is a separate booklet 
that is also delivered with this extractor hood. Carefully read these instructions before installing and commissioning the 
telescopic hood. It is recommended to have one or more qualified persons carry out the installation only. 

Carefully take the hood out of the packaging. 

The hood is to be used above a cooking plate and/or domino and is intended for household use only. Types 661, 662 and 
663 are intended for integration into a cabinet 60 cm wide and types 691, 692 and 693 are for integration into a cabinet 
90 cm wide. The extractor hood fills up the rear-most part of the cabinet, allowing you to use the front part of the cabinet 
for storage. 

The recommended mounting height for an electric or ceramic cooking plate is min. 600 mm and max. 750 mm. The 
mounting height for a gas or induction cooking plate is min. 650 mm and max. 750mm.

Important before mounting
Pages 2 and 3 of these mounting instructions show the mounting drawings. Observe the following mounting tips before 
starting the mounting activities:
•  For easier mounting of the telescopic hood it is recommended to do this with at least 2 persons.
•  Check if all mounting materials have been supplied using the drawings on page 2.
•  Position the wall socket such, that it is near the telescopic hood.
 
Exhaust or recirculation
Before starting any mounting activities, you must have made the choice if you are going to make an exhaust duct to the 
outside or if you are going to use the wall-mounted hood as a recirculation extractor hood. If you opt for recirculation, 
Novy can supply the recirculation set with item number 662.400 for the models 661, 662 and 663 and the recirculation set 
with item number 692.400 for the models 691, 692 and 693. 

INSTALLATION

Following the mounting drawings on pages 2 and 3.

Recess size: 
661-662-663:  

560-570 mm x 180 mm

691-692-693:  

860-870 mm x 180 mm

•  The extractor hood should be positioned so that the front of the front plate in the closed position is level with the 

front of the cabinet door.

•  A wall socket must be near the telescopic unit. If necessary, the hood must be able to be disconnected. The ex-

tractor hood has a cable with earthed plug and must be connected with an earthed wall socket. Replacement of 
the connection cable is to be done by a qualified installer. The amperage and the energy consumption have been 
indicated on the specification label attached to the inside of the extractor hood.

•  Note: with the type 662, 663, 692 and 693, the connecting spout for the drain channel protrudes at the front mak-

ing the storage space in the front of the cabinet smaller.

The two suspension brackets (603020) are fastened on either side in the side wall of the kitchen cabinet using  2 x 
2 pan head 4.2 x 9.5 mm screws (906151). Ensure during this assembly that the drawings are for the correct model 
number!

Position the extractor hood in the cut-away of the kitchen cabinet and push it upwards. The clamps on the sides of 
the built-in unit are resting on the sides of the kitchen cabinet. The aid of  tightening the screws of the clamps on the 
extractor hood it can be securely mounted in the cabinet.

The mounting holes become visible after sliding out the drawer. Here the extractor hood is secured to the bottom of 
the cabinet with stainless steel 3.5 x 16 mm wood screws (906140). For the 60 cm wide hoods there are 4 screws 
and for the 90 cm wide hoods there are 6 screws.

You can attach the decorative strip if required and depending on the depth of the kitchen cabinet. The distance be-
tween the back of the cooker hood and the wall may amount to a maximum of 80 mm. Cut the decorative strip to the 
required width. Warning, do not the cut the side with the raised edge! Warning, do not the cut the side with the raised 
edge! Remove the protective layer on the upper side of the tape.

1

2

3

4

5

Summary of Contents for 661/15

Page 1: ...hriften p 4 Nederland FR France Instructions d installation p 6 Belgique Suisse EN English Installation instructions p 8 DE Deutschland Montageanleitung p 10 Belgien sterreich Schweiz 661 15 662 15 66...

Page 2: ...662 663 Type 691 692 693 Type 661 Type 662 663 Type 691 692 693 4 x 906140 4 x 906140 6 x 906140 6 x 906151 4 x 906151 8 x 906151 1 x 801006 1 x 801006 1 x 801006 3 x 906188 3 x 906188 4 x 906188 2 x...

Page 3: ...3 8...

Page 4: ...00 voor de modellen 661 662 en 663 en de recirculatie kit met artikelnummer 692 400 voor de modellen 691 692 en 693 INSTALLATIE Volg de montage tekeningen op pagina 2 3 Uitsparingsmaat 661 662 663 560...

Page 5: ...er door de buitengevel gebruik van het buitenmuurrooster Bij gebruik van een plat afvoerkanaal Gebruik platte kanalen met afgeronde hoeken en luchtgeleiders in de bochten Deze kanalen zijn verkrijgbaa...

Page 6: ...r opt pour la r alisation d un conduit d vacuation vers l ext rieur ou si vous allez utiliser la chemin e murale comme hotte recyclage Si vous optez pour la recirculation Novy propose le kit de recycl...

Page 7: ...e et le plus direct possible vers l ext rieur vitez les coudes 90 R alisez des coudes ouverts pour un bon acheminement de l air En cas d vacuation au travers d un mur vide d air assurez vous que le co...

Page 8: ...ecirculation set with item number 692 400 for the models 691 692 and 693 INSTALLATION Following the mounting drawings on pages 2 and 3 Recess size 661 662 663 560 570 mm x 180 mm 691 692 693 860 870 m...

Page 9: ...he outside wall use the outside wall grate When using a flat exhaust duct Use flat ducts with rounded corners and air conductors in the bends These ducts are to be obtained through Novy General Make t...

Page 10: ...beginnen muss festgelegt werden ob Sie einen Abluftkanal ins Freie legen oder die Wandhaube als Umluftger t verwenden werden Wenn Sie eine Umluftl sung w nschen k nnen Sie bei Novy f r die Modelle 661...

Page 11: ...Kan le sind bei Novy erh ltlich Allgemeine Informationen Machen Sie den Kanal so kurz wie m glich und f hren Sie die Abluft mit m glichst wenig Kurven nach drau en Vermeiden Sie rechtwinklige Kurven...

Page 12: ......

Page 13: ......

Page 14: ...pr avis la construction et les prix de ses produits Die NOVY AG beh lt sich das Recht vor zu jeder Zeit und ohne Vorbehalt die Konstruktion und die Preise ihrer Produkte zu ndern NOVY nv Noordlaan 6...

Reviews: