Figure3-5.
Spindle / output parameter configuration (Spindle/OUT)
Spindle parameters specific definition reference table 3-4.
No.
Mark
Definition
Range
1
Max Speed
The max spindle speed
100-40000
2
Default Speed
The default spindle speed
0-40000
3
M3/4 Delay
Delay time of M3/4 instruction
0-8
Table 3-4.
Spindle parameter configuration
NCD02's spindle speed regulation output is 0-10V voltage, output voltage and maximum
spindle speed and default spindle speed (current speed) are related, the specific formula is:
output voltage (VSO) =10*default spindle speed (current speed F) / maximum spindle speed (F
max). For example, the current speed is F=20000, the maximum spindle speed F max=40000,
at this time, the spindle output voltage is VSO=10*20000/40000=5V.
The M3/4 delay time is the time between running the G code in the M3/4 time to the
actual execution of the IO output.