Chapter3 Softwar
e & config
Manual of NCH02
- 26 -
that the output level is maximum when no
pulse.
6
Dir Level
The direction level is 0. When the axis goes to
the coor movement, the direction
signal output level 0V, 1 indicates that the
direction signal output level is the maximum
when the axis moves towards the coor
movement.
1/0
7
BL Enable
Backlash Enable, 1: enable; 0: disable
1/0
8
BL Length
Backlash Length, The unit is mm
0-10
Table 3-2.
motor parameter configuration
3.3.2 Input parameter configuration (INPUT)
The input parameter configuration page is shown in Figure 3-4. This page list specific
parameters by row, and list number axis by column. The parameters of the axis can be adjusted
by the knob.