3.8. Alarm Configuration
3.8.1. Alarm I/O
In
Alarm I/O
menu you can set following alarm parameters:
ALARM IN
- Default number of alarm input ID is 1.
NAME
- to set the alarm input
NAME
, please click the box next to
NAME
and type any name from
keyboard.
VALID VOLTAGE LEVEL
-
high
and
low
options are available. When you select
high
, normal input
state is high (alarm signal is triggered when the voltage is lower than 12V), when you select
low
,
normal input state is low (alarm signal is triggered with 12V voltage).
ALARM OUT
- Default number of alarm output ID is 1.
NAME
- to set the alarm output
NAME
, please click the box next to
NAME
and type any name from
keyboard.
VALID SIGNAL
-
close
and
open
modes are available. When you select
close
, the alarm output is
normally turned on. When you select
open
, the alarm output is normally turned off.
ALARM OUT MODE
-
SWITCH MODE
and
PULSE MODE
are available. When you select SWITCH
MODE
you can adjust only
ALARM TIME
. When you select PULSE MODE, set the ALARM TIME to
0 (save alarm state till frequency or alarm input change) and adjust
FREQUENCY.
FREQUENCY
—
time to change a state of the alarm output
.
ALARM TIME
- output alarm duration.
MANUAL CONTROL -
press
START
or
STOP
button to change alarm out state.
WWW INTERFACE - WORKING WITH IP CAMERA