background image

All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o. 

 

 

12

 

NVIP

-

2ATM

-

6501/F

  

 

Quick start guide

   

 

version 1.0

 

All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o. 

 

 

12

 

2.7. Security recommendations for

 

network architecture and

 

configuration 

 

 

CAUTION

!

 

Below  are  shown  security  recommendations  for

 

network  architecture  and

 

configuration 

of

 

CCTV

 

systems

 

that  are  connected  to

 

the  Internet

 

to

 

reduce  the  risk 

of

 

unauthorized

 

interference with the

 

system

 

by a third party.

 

 

1.

 

Absolutely  change  the  default

 

passwords

 

and

 

user

 

names

 

(if  the  device

 

gives

 

this  possibility)  of 

all

 

applied

 

network  devices  (recorders,

 

cameras,  routers,

 

network  switches,  etc.)

 

to

 

the 

severely

 

complexity  password.

 

Use  lowercase  and

 

uppercase  letters,

 

numbers,  and

 

special  characters 

if

 

there is such possibility.

 

2. Depending on the available functionality in the order to restrict access to the used network devices at 

the administrator account level, it is recommended to configure the users accounts accordingly.

 

3.  Do  not  use  DMZ  function  (Demilitarized  zone)  in  your  router.  Using  that  function  you  open  the 

access  to  recorder  system  from  the  Internet  on  all  ports,  which  gives  possibility  for  an  unauthorized 

interference with the system. 

 

Instead of

 

DMZ

 

use

 

port forwarding

 

redirect only the ports which are

 

necessary for the performance 

of

 

the

 

connection (detailed

 

information about ports of communication

 

in different

 

models of

 

recorders, 

cameras,

 

etc.

 

can be found in the operating instructions). 

 

4. Use routers with firewall function and make sure it is enabled and properly configured.

 

5.  It  is  recommended  to  change  the  default  network  communication  port  numbers  of  used  devices 

if

 

there is such possibility.

 

6. If used

 

network devices

 

has

 

a

 

UPnP

 

feature

 

and

 

it is not

 

used,

 

turn it off.

 

7. If used

 

network devices

 

has

 

a

 

P2P

 

feature

 

and

 

it is not

 

used,

 

turn it off.

 

8. If used network devices support HTTPS protocol for connection, it is recommended to use it.

 

9. If used network devices support IP filtering for authorized connections function, it is recommended 

to use it.

 

10.  If used recorder has  two network interfaces it is recommended to use both of them to physically 
separate  network  for  cameras  and  network  for  Internet  connection.  The  only  device  in  the  system, 
accessible from Internet will be recorder 

-

 there will be no physically access directly to any camera.

 

START

-

UP AND INITIAL CAMERA CONFIGURATION

 

Summary of Contents for NVIP-2ATM-6501/F

Page 1: ...NVIP 2ATM 6501 F Quick start guide...

Page 2: ...DER THE RIGOR OF EXCLUDING THE MANUFACTURER S RESPONSIBILITY FOR THE RESULTS OF SUCH AN ACTION DIRECTIVE 2014 30 EU OF THE EUROPEAN PARLIMENT AND OF THE COUNCIL of 26 February 2014 on the harmonisatio...

Page 3: ...in accordance with the user s manual 5 The device should be disconnected from power sources during maintenance procedures 6 Usage of additional devices and components neither provided nor recommended...

Page 4: ...rnet cable connection 9 2 4 Camera mounting 9 2 5 Starting the IP camera 10 2 6 Initial configuration via the web browser 11 2 7 Security recommendations for network architecture and configuration 12...

Page 5: ...265 Smart MJPEG G711 Max video resolution up to 1920 x 1080 Multi streaming compression resolution speed and quality defined individually for each video stream ROI functions Motion detection Privacy Z...

Page 6: ...s Multistreaming Mode 3 streams Video Audio Compression H 264 H 264 H 264 Smart H 265 H 265 H 265 Smart MJPEG G 711 Number of Simultaneous Connections max 8 Bandwidth 24 Mb s in total Network Protocol...

Page 7: ...supplier for further assistance The power supply is not included with the camera so the user is obliged to provide it himself A suitable power supply should meet the conditions described in section 2...

Page 8: ...fore starting the device familiarize yourself with the description and the role of particular inputs outputs and adjusting elements that the device is equipped with 2 1 Description of connectors and c...

Page 9: ...the hermetic socket 3 screw the connector cover 2 and than the nut 1 NOTICE The camera housing is not hermetically sealed Do not install the camera outdoors or in places exposed to moisture 2 4 Camer...

Page 10: ...ended way to start an IP camera and perform its configuration is a direct connection to the network switch which is not connected to other devices To obtain further information about network configura...

Page 11: ...a ranges from 192 168 1 2 to 192 168 1 254 for example 192 168 1 60 It is not allowed to set the same addresses for camera and PC computer You can either set a network configuration IP address gateway...

Page 12: ...order system from the Internet on all ports which gives possibility for an unauthorized interference with the system Instead of DMZ use port forwarding redirect only the ports which are necessary for...

Page 13: ...ction with IP camera via web browser Connecting to the camera for the first time Enter the IP address of the camera default 192 168 1 200 in the address bar of the web browser If the address is correc...

Page 14: ...ssword twice and confirming it with the OK button the administrator password will be saved the window will close and the login screen will be displayed Logging in to the camera for the first time In t...

Page 15: ...swers is essential to recovering the administrator password Plug in installation If the browser has no connected to any of the 6000 series cameras so far or if an older version of the plug in is insta...

Page 16: ...click Install button to install plug in After installation click the Finish button to close the installer and refresh the browser window you can also close and restart the browser If after installati...

Page 17: ...displayed stream and fluency Allow to change the displayed stream to Main stream Sub stream Allow you to choose between Real time Balanced and Fluent fluency 3 Alarm icons icons showing the current st...

Page 18: ...ard tab 6 FACTORY SETTINGS RESTORING Restoring factory settings of the IP camera restores all default settings This process takes about two minutes NOVUS NVIP 2ATM 6501 F cameras allow to restore defa...

Page 19: ...er allows you to optionally keep some settings such as network settings To restore default settings go to Maintenance Backup and Restore tab 6 3 Hardware factory settings restoring In order to restore...

Page 20: ...2022 09 14 DK MK AAT SYSTEMY BEZPIECZE STWA Sp z o o 431 Pulawska St 02 801 Warsaw Poland tel 4822 546 0 546 kontakt aat pl www novuscctv com...

Page 21: ...NVIP 2ATM 6501 F Skr cona instrukcja obs ugi...

Page 22: ...tycznej Dz U L 096 z 29 3 2014 s 79 106 z p niejszymi zmianami zwana Dyrektywa EMC DYREKTYWA PARLAMENTU EUROPEJSKIEGO I RADY 2012 19 UE z dnia 4 lipca 2012 r w sprawie zu ytego sprz tu elektrycznego i...

Page 23: ...ci konserwatorskich urz dzenie musi by od czone od zasilania 6 Nie wolno stosowa adnych dodatkowych urz dze lub podzespo w nie przewidzianych i nie zalecanych przez producenta 7 Nie wolno u ywa kamery...

Page 24: ...ruchomienie kamery IP 10 2 6 Konfiguracja parametr w przy u yciu przegl darki internetowej 11 2 7 Zalecenia dotycz ce bezpiecze stwa sieci 12 3 PO CZENIA SIECIOWE ZA POMOC PRZEGL DARKI WWW 13 3 1 Zale...

Page 25: ...do 1920 x 1080 Mo liwo definiowania kompresji rozdzielczo ci pr dko ci i jako ci dla ka dego strumienia Obszar obserwacji ROI Detekcja ruchu Strefy prywatno ci Przesy anie wideo w standardzie RTSP Fu...

Page 26: ...ielostrumieniowy 3 strumienie Kompresja wideo audio H 264 H 264 H 264 Smart H 265 H 265 H 265 Smart MJPEG G 711 Liczba jednoczesnych po cze maks 8 Przepustowo cznie 24 Mb s Obs ugiwane protoko y sieci...

Page 27: ...silacz nie wchodzi w sk ad wyposa enia kamery z tego wzgl du nale y si w niego zaopatrzy we w asnym zakresie Zasilacz powinien spe nia warunki opisane w punkcie 2 2 Pod czenie zasilania na nast pnej s...

Page 28: ...dzenia Przed uruchomieniem urz dzenia nale y zapozna si z opisem i rol poszczeg lnych wej wyj oraz element w regulacyjnych w kt re wyposa one s kamery 2 1 Opis z cz elektrycznych oraz wyposa enia kame...

Page 29: ...zda hermetycznego 3 przykr ci g wn os on 2 a nast pnie nakr tk 1 UWAGA Obudowa kamery nie jest hermetyczna Nie nale y instalowa kamery na zewn trz i w miejscach nara onych na dost p wilgoci 1 2 3 1 2...

Page 30: ...nfiguracji kamery IP jest pod czenie jej do komputera PC lub laptopa w wydzielonym prze czniku PoE do kt rego nie ma pod czonych innych urz dze W celu uzyskania danych potrzebnych do konfiguracji siec...

Page 31: ...ego samego jak adres kamery Wykorzystuj c po czenie przez przegl dark internetow Internet Explorer lub oprogramowanie NMS nale y ustawi docelow konfiguracj sieciow adres IP mask sieci bram serwery DNS...

Page 32: ...iu u atwia ewentualn nieautoryzowan ingerencj w system Zamiast wykorzystywania funkcji DMZ nale y zastosowa przekierowanie port w Przekierowane powinny zosta jedynie porty niezb dne do realizacji po c...

Page 33: ...oc przegl darki internetowej Pierwsze po czenie si z kamer W pasku adresu przegl darki WWW nale y wpisa adres IP kamery domy lnie 192 168 1 200 Je li podany adres jest prawid owy i docelowe urz dzenie...

Page 34: ...i zatwierdzeniu przyciskiem OK has o administratora do konta zostanie zapisane okno zamknie si i wy wietli si ekran logowania Pierwsze logowanie si do kamery W oknie logowania nale y w pole Nazwa wpis...

Page 35: ...na do odzyskania has a administratora Instalacja dodatku plug in Je li do tej pory przegl darka nie czy a si z adn z kamer serii 6000 lub je li jest zainstalowana starsza wersja plug ina w oknie zdaln...

Page 36: ...dodatek Po zako czeniu instalacji nale y klikn przycisk Finish oraz od wie y okno przegl darki mo na tak e zamkn i uruchomi ponownie przegl dark Je eli po instalacji i od wie eniu okna przegl darki n...

Page 37: ...strumienia oraz buforowania Umo liwiaj wyb r strumienia Strumie g wny Pomocniczy 1 lub Pomocniczy 2 Pozwalaj wybra opcj buforowania Na ywo Standard oraz P ynnie 3 Ikony powiadomie ikony przedstawiaj...

Page 38: ...CANIE USTAWIE FABRYCZNYCH KAMERY Kamery NVIP 2ATM 6501 F marki NOVUS umo liwiaj resetowanie ustawie programowo z poziomu NMS IPTool programowo z poziomu przegl darki sprz towo przy u yciu przycisku re...

Page 39: ...ie z pomini ciem niekt rych ustawie np sieciowych Kamera zostanie ponownie uruchomiona po ok 1 minucie Opcja do programowego przywr cenia ustawie fabrycznych znajduje si w zak adce Konserwacja Kopia z...

Page 40: ...p z o o ul Pu awska 431 02 801 Warszawa Polska tel 22 546 07 00 faks 22 546 07 59 www novuscctv com AAT SYSTEMY BEZPIECZE STWA Sp z o o ul Pu awska 431 02 801 Warszawa Polska tel 22 546 0 546 kontakt...

Reviews: