NVAHD-2DN3202MV/IR-1-II - User’s manual ver. 1.0
All rights reserved © AAT Holding S.A.
14
SETTINGS
LANGUAGE
-
switches between OSD languages: Polish, English, Russian and others.
DEFECT
- allows to adjust parameters used in Dead Pixel Correction function:
LIVE DPC
- sets parameters of the defective pixel correction function in real time. Selecting
ON
and
giving
ENTER
command opens a submenu for setting the gain level and the level of correction.
WHITE DPC
- allows to a correct "hot pixels". Selecting
ON
and giving
ENTER
command opens
a submenu:
Here you can specify the size and location of the zone in which the correction will be made
(position
POS/SIZE
), then define the level of correction and amplification (
LEVEL
and
AGC
positions) and set
SENS-
UP
option (if camera uses
SENS-UP
setting). Then select
START
position and use
ENTER
command, cover the lens tightly and give
ENTER
command again.
After correcting process the camera returns to the
DPC WHITE
menu. In the
DPC VIEW
you can
check the correction effect and, if needed repeat the operation with different settings.
BLACK DPC
- allows to correct (mask) dead pixels. Selecting ON and using
ENTER
command
opens a submenu which define the size and location of the zone in which the correction is made
(position POS/SIZE), then define the compensation level (position LEVEL). Then select
START
position and use
ENTER
command and wait for the end of the operation. In the
DPC VIEW
check
the correction effect and, if needed repeat the operation with different settings.
RS485
- option disabled in this model.